2018
DOI: 10.1007/s10404-018-2145-2
|View full text |Cite
|
Sign up to set email alerts
|

Study on the statistical intensity distribution (SID) of fluorescent nanoparticles in TIRFM measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

4
9
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(14 citation statements)
references
References 33 publications
4
9
1
Order By: Relevance
“…4(c) is shown the corresponding temporal evolution of the reduced dispersion coefficient for z 0 = 600±15 nm. While the data does not reach exactly (especially at early times) the theoretical prediction for the dot condition due to the polydispersity of the particles (and thus non-unique altitudes for a given intensity [43]), it is systematically below the one for the half-line condition and approaches the τ 2 asymptotic behaviour predicted by Eq. 3 for n = 0.…”
contrasting
confidence: 56%
See 1 more Smart Citation
“…4(c) is shown the corresponding temporal evolution of the reduced dispersion coefficient for z 0 = 600±15 nm. While the data does not reach exactly (especially at early times) the theoretical prediction for the dot condition due to the polydispersity of the particles (and thus non-unique altitudes for a given intensity [43]), it is systematically below the one for the half-line condition and approaches the τ 2 asymptotic behaviour predicted by Eq. 3 for n = 0.…”
contrasting
confidence: 56%
“…Figure 1(c) shows the streamwise velocity profiles for 55 nm-radius particles in water and several pressure drops. The solid lines show that the profiles are well approximated by linear functions (see SI and [35,43] for a discussion of the small non-linearities). The spread of v xintercept values arises from the spread of values for I 0 at each pressure, z = 0 being taken as the mean of Π log I 0 over the different ∆P ; z = 0 is thus resolved to within 20 nm of the solid/liquid interface assuming no slip [35] as justified in the SI.…”
mentioning
confidence: 98%
“…To investigate the effects of defocussing and polydispersity, we have used 63 the signal intensity distribution analyses of ref. 62, simultaneously fitting the distribution of intensities and velocity profiles and find good agreement with the slopes measured here, within 10% or so and not varying systematically with the imposed pressure.…”
Section: Limitations Of the Particle Altitude Determinationsupporting
confidence: 78%
“…6 2)), which are validated by the agreement of our measured water viscosity using TIRFM with accepted values. More directly, and while not shown here, we have verified that the angles thus measured in situ are in agreement with the typical method of projecting the laser through a half sphere placed atop the objective, 48,62 with the horizontal position of the laser measured as a function of x M .…”
Section: Angle Measurementsupporting
confidence: 78%
See 1 more Smart Citation