Study on the Control Method and Optimization Experiment of Prostate Soft Tissue Puncture

Abstract: In the treatment of prostate cancer patients, surgery of radioactive seed implantation with the puncture robots is an effective treatment method. However, when the puncture needle enters the lesion tissue, there are complicated forces between the needle body and the soft tissue, which leads to the drift of the prostate and the deflection of the puncture needle, thereby affecting the puncture accuracy. In order to improve the positioning accuracy and ensure the best treatment effect, a sine rotation continuous … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 40 publications
(49 reference statements)
0
7
0
Order By: Relevance
“…To approximate the real prostate soft tissue, the bionic soft tissue model used in this experiment was made according to the requirements in ref. [9] (the elastic modulus parameters are consistent).…”
Section: Experiments Equipmentmentioning
confidence: 75%
See 3 more Smart Citations
“…To approximate the real prostate soft tissue, the bionic soft tissue model used in this experiment was made according to the requirements in ref. [9] (the elastic modulus parameters are consistent).…”
Section: Experiments Equipmentmentioning
confidence: 75%
“…The silicone bionic soft tissue used in the experiment was made according to ref. [9] (it is required to approximate the elastic modulus value of human prostate soft tissue as closely as possible), and a lot of this bionic soft tissue will be used in multiple puncture experiments. Therefore, the elastic moduli of the bionic soft tissues with each other will inevitably have slight differences in mass fabrication.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…To ensure the accuracy of puncture, parameters such as rotation frequency, rotation angle, and puncture speed were analysed and optimized, and soft-tissue puncture tests of pig kidneys were carried out, which verified the rationality and accuracy of this method. 108 The research progress of automatic interventional medical devices is arranged according to the published year, as shown in Table 3.…”
Section: Accuracy and Safety Of Automatic Equipmentmentioning
confidence: 99%