2013
DOI: 10.1016/j.nima.2013.07.027
|View full text |Cite
|
Sign up to set email alerts
|

Study of low frequency acoustic signals from superheated droplet detector

Abstract: The bubble nucleation process in superheated droplet detector (SDD) is associated with the emission of an acoustic pulse that can be detected by an acoustic sensor. We have studied the neutron and gamma-ray induced nucleation events in a SDD with the active liquid R-12 (CCl 2 F 2 , b.p. -29.8 o C) using a condenser microphone sensor. A comparative study in the low frequency region (~ 0-10kHz) for the neutron and gamma-ray induced nucleation is presented here. From the analysis of the waveforms we observe a sig… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 38 publications
0
5
0
Order By: Relevance
“…Here the primary harmonic frequency (f), defined as the frequency corresponding to the highest peak in the fast Fourier transform (FFT) of the waveform, is obtained for all the acquired waveform data. For a particular SDD at a given operating condition the primary harmonic shows a distribution [13]. Here we observe that pulses from different SDDs have primary harmonics in different frequency regions [Fig.…”
Section: Variation Of the Primary Harmonic Of The Signal With Operati...mentioning
confidence: 69%
See 4 more Smart Citations
“…Here the primary harmonic frequency (f), defined as the frequency corresponding to the highest peak in the fast Fourier transform (FFT) of the waveform, is obtained for all the acquired waveform data. For a particular SDD at a given operating condition the primary harmonic shows a distribution [13]. Here we observe that pulses from different SDDs have primary harmonics in different frequency regions [Fig.…”
Section: Variation Of the Primary Harmonic Of The Signal With Operati...mentioning
confidence: 69%
“…4). For a particular type of detector, at a given operating temperature and pressure, τ usually shows a distribution [13]. The average values of τ at different pressure for R-12, R- we observe that for all the SDDs at a given operating temperature τ initially decreases with increase in operating pressure up to about 3 kg cm -2 and then it does not change much with increase in pressure.…”
Section: Variation Of the Decay Time Constant Of The Signal With Oper...mentioning
confidence: 77%