2003
DOI: 10.1541/ieejpes.123.1373
|View full text |Cite
|
Sign up to set email alerts
|

Study of Flashover Model on Overhead Distribution Lines

Abstract: We have carried out analysis of lightning surge on overhead distribution lines by means of EMTP. We made a model for electric breakdown of a 14‐m concrete pole with impulse voltage (rise time: 2 μ s) applied to the outer surface at the top of the concrete pole. We found that the transient impedance of the breakdown increased linearly before the breakdown and decreased exponentially after the breakdown. The measured voltage and current waveforms correspond to the calculated waveforms by regarding the impedance … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2013
2013
2015
2015

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…In addition, there have been many investigations of lighting protection of distribution lines [13][14][15][16][17][18], but few dealing with creeping discharges on conductor surfaces. Lightning often occurs during rain, so that water drops adhere to the wire surface and create wet conditions.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, there have been many investigations of lighting protection of distribution lines [13][14][15][16][17][18], but few dealing with creeping discharges on conductor surfaces. Lightning often occurs during rain, so that water drops adhere to the wire surface and create wet conditions.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, creeping discharge properties under wet conditions remain unclear not only for cylindrical dielectrics such as wires, but also for flat surfaces. In addition, there have been many investigations of lighting protection of distribution lines [13][14][15][16][17][18], but few dealing with creeping discharges on conductor surfaces.…”
Section: Introductionmentioning
confidence: 99%
“…There are only a few reports on the creeping discharge for the lightning surge with various T f , because actual inductive lightning surges usually are simulated by a standard lightning impulse voltage (1.2/50 μs). While a lot of studies of the distribution line due to the direct or inductive lightning stroke have been performed on the protection of lightning damages , studies on the creeping discharges at the cable surface caused by the lightning strike are very few, particularly, the effect of T f on the creeping discharge has not been clarified for the present.…”
Section: Introductionmentioning
confidence: 99%