DOI: 10.1016/j.ejmp.2016.05.052
|View full text |Cite
|
Sign up to set email alerts
|

Study of commercial detector responses in non-equilibrium small photon fields of a 1000 MU/min CyberKnife system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
9
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 32 publications
1
9
0
Order By: Relevance
“…The SFD silicon chip has a side length of around 1.1 mm measured from a CT image and is typically simulated as disks of a diameter around 1.0 mm . The EDGE detector has been modeled with a slightly larger chip of 1.3‐mm side length . The 60012 also has been reported to be simulated with a diameter of 1.5 mm .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The SFD silicon chip has a side length of around 1.1 mm measured from a CT image and is typically simulated as disks of a diameter around 1.0 mm . The EDGE detector has been modeled with a slightly larger chip of 1.3‐mm side length . The 60012 also has been reported to be simulated with a diameter of 1.5 mm .…”
Section: Discussionmentioning
confidence: 99%
“…25,26 The EDGE detector has been modeled with a slightly larger chip of 1.3-mm side length. 27 The 60012 also has been reported to be simulated with a diameter of 1.5 mm. 26,28 Additionally, the unshielded 60012 still contains some high Z material in the form of a filter in the vicinity of the silicon chip, which is described in detail for the successor model 60017 in.…”
Section: Discussionmentioning
confidence: 99%
“…It was shown that it is possible to design a 'correction-free' detector, though, with the addition of low density media to the high density detector components 11 . However, it must be verified that these modifications are correctly compensating whatever the beam quality and measurements conditions 12 . 2D monolithic silicon diode array detectors, with either 2 mm and 3 mm pitch, have been shown to be promising as dosimeters by several groups 13,14 .…”
Section: Introductionmentioning
confidence: 99%
“…As previously suggested by other authors, it would be necessary to verify that the introduced air gap is appropriate under any beam energy and measurement condition [28]. Further study will be dedicated to improving the current understanding of the relationship existing between the required amount of air gap, detector design, beam energy and measurement condition.…”
Section: Discussionmentioning
confidence: 90%