The therapeutic management of severe radiation burns remains a challenging issue. Conventional surgical treatment (excision and skin autograft or rotation flap) often fails to prevent unpredictable and uncontrolled extension of the radiation necrotic process. We report here an innovative therapeutic strategy applied to the victim of a radiation accident (December 15, 2005) with an iridium gammagraphy radioactive source (192Ir, 3.3 TBq). The approach combined numerical dosimetry-guided surgery with cellular therapy using mesenchymal stem cells. A very severe buttock radiation burn (2000 Gy at the center of the skin surface lesion) of a 27-year-old Chilean victim was widely excised (10 cm in diameter) using a physical and anatomical dose reconstruction in order to better define the limit of the surgical excision in apparently healthy tissues. A secondary extension of the radiation necrosis led to a new excision of fibronecrotic tissues associated with a local cellular therapy using autologous expanded mesenchymal stem cells as a source of trophic factors to promote tissue regeneration. Bone marrow-derived mesenchymal stem cells were expanded according to a clinical-grade technique using closed culture devices and serum-free medium enriched in human platelet lysate. The clinical evolution (radiation pain and healing progression) was favorable and no recurrence of radiation inflammatory waves was observed during the 11 month patient's follow-up. This novel multidisciplinary therapeutic approach combining physical techniques, surgical procedures and cellular therapy with adult stem cells may be of clinical relevance for improving the medical management of severe localized irradiations. It may open new prospects in the field of radiotherapy complications.
Four sets of correction factors needed to apply the new small field dosimetry formalism are provided for several active detectors. A protocol for small photon beams OF determination based on passive dosimeters measurements has been recently proposed to French radiotherapy treatment centers.
A European consensus concerning the medical management of mass radiation exposure was obtained in 2005 during a conference held by the European Group for Blood and Bone Marrow Transplantation, the Institute of Radioprotection and Nuclear Safety, and the University of Ulm. At the conference, a two-step triage strategy to deal with large masses of radiation-exposed patients was designed. The first step of this strategy concerns the first 48 h and involves scoring the patients exclusively on the basis of their clinical symptoms and biological data. This allows the non-irradiated bystanders and outpatient candidates to be identified. The remaining patients are hospitalized and diagnosis is confirmed after the first 48-h period according to the METREPOL (Medical Treatment Protocols for radiation accident victims) scale. This grades the patients according to the severity of their symptoms. It was also agreed that in the case of acute radiation syndrome (ARS), emergency hematopoietic stem cell (HSC) transplantation is not necessary. Instead, cytokines that promote hematological reconstruction should be administered as early as possible for 14-21 d. Crucial tests for determining whether the patient has residual hematopoiesis are physical dose reconstructions combined with daily blood count analyses. It was agreed that HSC transplantation should only be considered if severe aplasia persists after cytokine treatment. Two recent cases of accidental radiation exposure that were managed successfully by following the European consensus with modification are reviewed here. Thus, a European standard for the evaluation and treatment of ARS victims is now available. This standard may be suitable for application around the world.
Many accidents in radiotherapy have been reported in France over the last years. This is due to the recent legal obligation to declare to the national safety authorities any significant incident relative to the use of ionising radiation including medical applications. The causes and consequences of the most serious events in radiotherapy are presented in this paper. Lessons can be learned from possible technical dysfunctions, from human errors or organisational weaknesses as to how such events can be prevented. The technical aspects are addressed here: in particular, dosimetric issues.
Recent developments of new therapy techniques using small photon beams, such as stereotactic radiotherapy, require suitable detectors to determine the delivered dose with a high accuracy. The dosimeter has to be as close as possible to tissue equivalence and to exhibit a small detection volume compared to the size of the irradiation field, because of the lack of lateral electronic equilibrium in small beam. Characteristics of single crystal diamond (tissue equivalent material Z = 6, high density) make it an ideal candidate to fulfil most of small beam dosimetry requirements. A commercially available Element Six electronic grade synthetic diamond was used to develop a single crystal diamond dosimeter (SCDDo) with a small detection volume (0.165 mm(3)). Long term stability was studied by irradiating the SCDDo in a (60)Co beam over 14 h. A good stability (deviation less than ± 0.1%) was observed. Repeatability, dose linearity, dose rate dependence and energy dependence were studied in a 10 × 10 cm(2) beam produced by a Varian Clinac 2100 C linear accelerator. SCDDo lateral dose profile, depth dose curve and output factor (OF) measurements were performed for small photon beams with a micro multileaf collimator m3 (BrainLab) attached to the linac. This study is focused on the comparison of SCDDo measurements to those obtained with different commercially available active detectors: an unshielded silicon diode (PTW 60017), a shielded silicon diode (Sun Nuclear EDGE), a PinPoint ionization chamber (PTW 31014) and two natural diamond detectors (PTW 60003). SCDDo presents an excellent spatial resolution for dose profile measurements, due to its small detection volume. Low energy dependence (variation of 1.2% between 6 and 18 MV photon beam) and low dose rate dependence of the SCDDo (variation of 1% between 0.53 and 2.64 Gy min(-1)) are obtained, explaining the good agreement between the SCDDo and the efficient unshielded diode (PTW 60017) in depth dose curve measurements. For field sizes ranging from 0.6 × 0.6 to 10 × 10 cm(2), OFs obtained with the SCDDo are between the OFs measured with the PinPoint ionization chamber and the Sun Nuclear EDGE diode that are known to respectively underestimate and overestimate OF values in small beam, due to the large detection volume of the chamber and the non-water equivalence of both detectors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.