2015
DOI: 10.18280/ijht.330122
|View full text |Cite
|
Sign up to set email alerts
|

Study of Co2 Fluid Density Calculation Model Based on Grayscale Image

Abstract: In order to get more accurate density calculation model of CO2 under different phases which are liquid, gas and supercritical state, the paper applies the relative error to measure the precision of the calculation model based on six typical cubic calculation models and the basic data which is from the U.S. National Institute of Standards and Technology (NIST). It presents a new method based on grayscale image, which is to show the relative error matrix as grayscale image and binary image. It will help to analy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…This is also the imaging method used for the point diagram in the third bars in Table. 1. RGB color format is used [11]. Blue (0, 0, 255) is used to show the water phase, green (0, 255, 0) to show the oil phase and red (255, 0, 0) to show the gas phase.…”
Section: Transformation From Attribute Value Of Node To Attribute Valmentioning
confidence: 99%
“…This is also the imaging method used for the point diagram in the third bars in Table. 1. RGB color format is used [11]. Blue (0, 0, 255) is used to show the water phase, green (0, 255, 0) to show the oil phase and red (255, 0, 0) to show the gas phase.…”
Section: Transformation From Attribute Value Of Node To Attribute Valmentioning
confidence: 99%
“…Over the years, many image segmentation methods have been developed to extract BGA solder joints from the X-ray images of printed circuit board (PCB), such as threshold segmentation and edge extraction, to name but a few [5][6][7][8][9][10][11][12]. The X-ray technique is adopted because it is impossible to find the defects in visible light.…”
Section: Introductionmentioning
confidence: 99%
“…The combined use of EPI and parallel acquisition technique SENSE can facilitate the scan speed and reduce the scan time to about 1/3 of the time using the conventional method. The combined approach removes the influence of motion artifacts, increases the spatial resolution of the images and ensures the quality of whole-body DWI (Dong et al, 2015;Kwee et al, 2008;Vargas et al, 2010;Yang et al, 2011;Jambawalikar et al, 2010;Tang and Chen, 2016;Zhou et al, 2012). DWIBS is very sensitive to tumor metastases of the whole body and therefore useful for detecting small metastatic foci.…”
Section: Introductionmentioning
confidence: 99%