Studies on a Wind Turbine Generating System that Employs a Thyristor Inverter

Abstract: SUMMARYA new wind turbine generating system that employs a current-source thyristor inverter is proposed, and the steady-state and dynamic performances for a practical system are discussed. The proposed system is essentially based on the shaft generator system that is widely used in large ships, and it has many features such as high reliability and generation of output power of high quality. It is shown that electric power with constant frequency and voltage with low distortion can be obtained by using this no… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2014
2014
2014
2014

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(12 citation statements)
references
References 4 publications
0
12
0
Order By: Relevance
“…As in the figure, jumps or sags in the inverter output line voltage waveform appear with the commutation of the inverter thyristor, and the total harmonic distortion is THD = 7.93%, which is relatively large. Although this THD is greater than 5%, which is the maximum standard value of THD when a wind turbine generator is interconnected with the grid, THD = 3.57% is obtained for the output line voltage waveform Vll of the system, which is sufficiently small, because of the function of the duplex reactor . Furthermore, while the inverter output current iU becomes rectangular as shown in the figure, since the inverter is of the current‐source type, the load current is nearly sinusoidal.…”
Section: Configuration Of Tested System and Steady‐state Characteristicsmentioning
confidence: 94%
See 4 more Smart Citations
“…As in the figure, jumps or sags in the inverter output line voltage waveform appear with the commutation of the inverter thyristor, and the total harmonic distortion is THD = 7.93%, which is relatively large. Although this THD is greater than 5%, which is the maximum standard value of THD when a wind turbine generator is interconnected with the grid, THD = 3.57% is obtained for the output line voltage waveform Vll of the system, which is sufficiently small, because of the function of the duplex reactor . Furthermore, while the inverter output current iU becomes rectangular as shown in the figure, since the inverter is of the current‐source type, the load current is nearly sinusoidal.…”
Section: Configuration Of Tested System and Steady‐state Characteristicsmentioning
confidence: 94%
“…Although safe commutation of the inverter becomes difficult at higher wind velocities, careful selection of Kd in Eq. , which can be adjusted by phase control of the thyristor rectifier, but is set constant here, makes stable operation possible .…”
Section: Configuration Of Tested System and Steady‐state Characteristicsmentioning