2017
DOI: 10.1038/pj.2017.30
|View full text |Cite
|
Sign up to set email alerts
|

Structure and properties of biocompatible poly(glycerol adipate) elastomers modified with ethylene glycol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
16
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 22 publications
2
16
0
Order By: Relevance
“…The synthesis of the hyperbranched PGA elastomer was carried out through a catalyst-free polycondensation at 150 °C under atmospheric pressure for 17 h, followed by applying a vacuum of 3 mm Hg for 4 h [ 78 ]. PGA prepolymer was then cross-linked by heating at 120 °C for 100 h to prepare an elastomeric material.…”
Section: Polyol Polyesters From Glycerol and Sugar Alcohols (Alditmentioning
confidence: 99%
“…The synthesis of the hyperbranched PGA elastomer was carried out through a catalyst-free polycondensation at 150 °C under atmospheric pressure for 17 h, followed by applying a vacuum of 3 mm Hg for 4 h [ 78 ]. PGA prepolymer was then cross-linked by heating at 120 °C for 100 h to prepare an elastomeric material.…”
Section: Polyol Polyesters From Glycerol and Sugar Alcohols (Alditmentioning
confidence: 99%
“…However, PGAd can also be prepared as a hyperbranched polymer. In a recent study, Navarro et al reported the synthesis of hyperbranched PGAd elastomer, using 1:1 and 0.6:1 Gly/AdA molar ratios, at 150 • C, at atmospheric pressure for 17 h and under high vacuum (3 mm Hg) for four more hours (Table 3) [53]. The M n of the obtained PGAd was higher at 1:1 molar ratio while the degree of branching was higher at 0.6:1 molar ratio.…”
Section: Hyperbranched Pgadmentioning
confidence: 99%
“…The degradation by-products of PGA are adipic acid and glycerol which are safe compounds as approved by FDA (Zhang et al, 2014) (5) The cytotoxicity of PGA has been determined earlier in our group (Kallinteri et al, 2005), and it showed a very low cell toxicity against Human Leukaemia cell line, HL60 cell and Human liver cell lines, HepG2 cells at the top dose of polymer NP, 100 times more of polymer amount required for a therapeutic nano-delivery system. Also, Navarro and his colleagues (Navarro et al, 2017) have used PGA elastomer and it was demonstrated to be non-cytotoxic to embryonic mouse fibroblasts (NIH/3T3) after seeding cells for 6 hours over PGA discs .…”
Section: Preparation and Characterization Of Nanoparticlesmentioning
confidence: 99%