1991
DOI: 10.1016/s0735-1097(10)80182-2
|View full text |Cite
|
Sign up to set email alerts
|

Stress echocardiography and the human factor: The importance of being expert

Abstract: The aim of this study was to evaluate how the diagnostic accuracy of a stress echocardiographic procedure, such as a dipyridamole echocardiography test, depends on the specific experience of the physician interpreting the test. Recordings of 50 consecutive dipyridamole echocardiographic tests were selected for the first part of the study. They were analyzed by 20 experienced echocardiographers with different backgrounds in stress echocardiography: 10 beginners (less than 20 stress studies interpreted with trai… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
221
3
9

Year Published

1991
1991
2009
2009

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 513 publications
(235 citation statements)
references
References 10 publications
2
221
3
9
Order By: Relevance
“…14,15 The sensitivity of this methodology is limited, because even severe stenosis may not cause a wall motion abnormality at rest. Accordingly, there is a strong need for techniques capable of extracting more information from ultrasound images that may provide additional insights into myocardial physiology.…”
Section: Discussionmentioning
confidence: 99%
“…14,15 The sensitivity of this methodology is limited, because even severe stenosis may not cause a wall motion abnormality at rest. Accordingly, there is a strong need for techniques capable of extracting more information from ultrasound images that may provide additional insights into myocardial physiology.…”
Section: Discussionmentioning
confidence: 99%
“…9 Resting left ventricular function was qualitatively evaluated by an experienced observer as normal, mild, moderately, or severely reduced, based on assessment of the extent of abnormal wall motion. Stress echocardiograms were interpreted by comparison of rest and stress images using the quad-screen digital display, with review of video-tape if desired.…”
Section: Echocardiographymentioning
confidence: 99%
“…First, central laboratory examination of stress echocardiograms was not available; therefore, interinstitutional variability in interpretation affects the results. However, interobserver agreement is substantially higher when explicit reading criteria, similar to those adopted in the current study, are used [38]. In addition, each interpreting cardiologist met quality control criteria before entering the study.…”
Section: Study Limitationsmentioning
confidence: 93%