2017
DOI: 10.15171/joddd.2017.027
|View full text |Cite
|
Sign up to set email alerts
|

Stress distribution pattern of screw-retained restorations with segmented vs. non-segmented abutments: A finite element analysis

Abstract: Background. Screw-retained restorations are favored in some clinical situations such as limited inter-occlusal spaces. This study was designed to compare stresses developed in the peri-implant bone in two different types of screw-retained restorations (segmented vs. non-segmented abutment) using a finite element model. Methods. An implant, 4.1 mm in diameter and 10 mm in length, was placed in the first molar site of a mandibular model with 1 mm of cortical bone on the buccal and lingual sides. Segmented and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

3
3
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 27 publications
3
3
0
1
Order By: Relevance
“…These results are consistent with those of previous studies [21,22]. A photoelastic stress analysis by Ochiai et al [21] showed that non-segmented abutments under vertical loading generate more stress in the bone compared to segmented abutments.…”
Section: Discussionsupporting
confidence: 92%
See 1 more Smart Citation
“…These results are consistent with those of previous studies [21,22]. A photoelastic stress analysis by Ochiai et al [21] showed that non-segmented abutments under vertical loading generate more stress in the bone compared to segmented abutments.…”
Section: Discussionsupporting
confidence: 92%
“…A photoelastic stress analysis by Ochiai et al [21] showed that non-segmented abutments under vertical loading generate more stress in the bone compared to segmented abutments. Another study suggested that segmented abutments show biomechanical benefits in terms of a decrease in stress concentration and microstrain in bone [22]. They found that a greater part of the stress might be detected in the prosthetic components (abutments and screws) before reaching the bone-implant contact area.…”
Section: Discussionmentioning
confidence: 99%
“…These results may be related to the segmented structure, which is capable to improve biomechanical behavior with the presence of two screwed connections in the conical abutment and increase the total area for stress/strain distribution and dissipation through the components (Camargos et al, 2016). These results are consistent with previous studies, which demonstrated that non-segmented abutments generate higher stress compared to segmented abutments (Ochiai et al, 2003;Aalaei et al, 2017).…”
Section: Discussionsupporting
confidence: 90%
“…Studies suggest that the use of the prosthetic segmented abutments is directly related to a better distribution of stress (Chun et al, 2005;Aalaei et al, 2017). The implant-abutment connection is believed to play an important role in the treatment outcome.…”
Section: Discussionmentioning
confidence: 99%
“…Dado semelhante pode ser encontrado em estudos utilizando de implantes envolvendo cargas oblíquas a 45º em carregamentos de 100 N de compressão, simulados em região de mandíbula, apresentaram valor máximo de tensão de von Mises em torno de 524 MPa 17 , o que representou uma diferença de 8,7% em relação à literatura. Valores aproximados puderam ser notados para a mesma situação em estudos realizados por Aalaei et al (2017) 18 , sendo que foi verificado nos pilares, máxima concentração de tensão de von Mises (430 MPa) 18 , confirmando que o presente estudo tem aproximação com os resultados encontrados na literatura em estudos similares.…”
Section: Discussionunclassified