2005
DOI: 10.1016/j.jbiomech.2004.05.036
|View full text |Cite
|
Sign up to set email alerts
|

Strain-rate dependent material properties of the porcine and human kidney capsule

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

9
90
1
1

Year Published

2006
2006
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 106 publications
(101 citation statements)
references
References 21 publications
9
90
1
1
Order By: Relevance
“…34 Having sufficient mechanical integrity to resist handling during implantation and in vivo loading is a requisite for scaffolding materials. 28 It has been reported that kidney 35 and liver 36,37 tissues have the maximum stress of 9.0 and 9.82 MPa, respectively. The PVA sponge fabricated in this study presented a maximum stress of 9.79 MPa, therefore, …”
Section: R E T R a C T E Dmentioning
confidence: 99%
“…34 Having sufficient mechanical integrity to resist handling during implantation and in vivo loading is a requisite for scaffolding materials. 28 It has been reported that kidney 35 and liver 36,37 tissues have the maximum stress of 9.0 and 9.82 MPa, respectively. The PVA sponge fabricated in this study presented a maximum stress of 9.79 MPa, therefore, …”
Section: R E T R a C T E Dmentioning
confidence: 99%
“…Rats were skeletally mature (17 weeks), male, and weight matched. Specimens were extracted from the tail and clamped immediately before mechanical testing using previously described soft tissue mounting techniques (Snedeker et al, 2005).…”
Section: Experimental Procedures Rat Tail Tendon Fascicle Preparationmentioning
confidence: 99%
“…Several groups (Dunn and Silver 1983;Hof 2003;Huang et al 2005;Klein et al 2005;Kuo et al 2001;Lally et al 2004;Provenzano et al 2002;Silver et al 2001;Suki et al 1994;Wu et al 2003) have reported findings on mechanical properties of some soft tissues, but most of their studies were focused on tendons, ligaments, cartilage, skin, muscles, lungs, or arteries, which, to some extent, have active force-generating mechanical properties. In contrast, just a few publications (Arbogast and Margulies 1998;Chen et al 1996;Darvish and Crandall 2001;Krouskop et al 1998;Liu and Bilston 2000;Nasseri et al 2002;Phipps et al 2005aPhipps et al , 2005bSnedeker et al 2005;Yang and Church 2006;Yeh et al 2002) presented quantitative results on the viscoelastic behavior of tissues such as brain, breast, prostate, liver, or kidney. Liu and Bilston (2000) studied the viscoelastic properties of bovine liver tissue with three testing methods: shear strain sweep oscillation, shear stress relaxation, and shear oscillation.…”
Section: Introductionmentioning
confidence: 99%
“…The mean Young's modulus values were 9.9 kPa and 6.6 kPa, respectively (Kemper et al 2004). Significant discrepancies were also found on the reported stiffness of kidney tissue (Erkamp et al 1998;Kruse et al 2000;Nasseri et al 2002;Snedeker et al 2005). The divergent reports of soft tissue properties are mainly caused by the different choices of testing techniques, tissue models, compression frequencies, temperature, sample variation, and other experimental factors.…”
Section: Introductionmentioning