2006
DOI: 10.1177/096369350601500401
|View full text |Cite
|
Sign up to set email alerts
|

Stereolithography Specimen to Calibrate Permeability Measurements for RTM Flow Simulations

Abstract: The simulation of a resin flow through a porous medium by FE-models has become a very important aspect for the design of a high-performance RTM produced composite part. The key parameter to perform RTM flow simulations is the fibre reinforcement permeability. Unfortunately, permeability measurements are not yet fully standardized and thus many different set-ups have been proposed. A major problem in comparing different set-ups has always been the fact that there exists no reliable reference material on which a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
0

Year Published

2009
2009
2014
2014

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(15 citation statements)
references
References 19 publications
1
14
0
Order By: Relevance
“…In Table 1, the cited principle permeability values for the unit cell are listed along with values obtained through the CFD simulations. As can be seen from the table, results for K 1 from simulation closely match that listed in the literature [9]. The observed small discrepancy is expected.…”
Section: Design and Manufacturing Of Rigid Calibration Tool 31 Validsupporting
confidence: 85%
See 3 more Smart Citations
“…In Table 1, the cited principle permeability values for the unit cell are listed along with values obtained through the CFD simulations. As can be seen from the table, results for K 1 from simulation closely match that listed in the literature [9]. The observed small discrepancy is expected.…”
Section: Design and Manufacturing Of Rigid Calibration Tool 31 Validsupporting
confidence: 85%
“…This gap was to be filled with a gasket as described in section 4.1. Similarly, the thickness of the material was less than the thickness [9] and the Fluent © simulation results for the original unit-cell. of the mold cavity.…”
Section: Designing a Calibration Tool For 1-d Flow Experimentsmentioning
confidence: 77%
See 2 more Smart Citations
“…The lattice‐like reference medium, based on the design proposed by Morren et al , was created by repeating a unit‐cell structure in plastic with stereo‐lithography (Fig. b), with the dimensions of each unit‐cell being much smaller than the overall medium dimensions.…”
Section: Methodsmentioning
confidence: 99%