1997
DOI: 10.1016/s0022-328x(96)06594-1
|View full text |Cite
|
Sign up to set email alerts
|

Stereochemical non-rigidity of N-(dimethylhalogenosilylmethyl)-N-(1-phenylethyl) acetamides in solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

1998
1998
2023
2023

Publication Types

Select...
3
3

Relationship

2
4

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 18 publications
0
12
0
Order By: Relevance
“…This method does not require the knowledge of the mechanism of the ligand‐site exchange; however, it allows an understanding what substituent effects influence the free energies of activation Δ G ≠ . The Δ G ≠ values for 13 series, taken from the literature are given in Tables . In the majority of cases the free energies Δ G ≠ were calculated from the data on the coalescence of the NMR signals.…”
Section: Calculation Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…This method does not require the knowledge of the mechanism of the ligand‐site exchange; however, it allows an understanding what substituent effects influence the free energies of activation Δ G ≠ . The Δ G ≠ values for 13 series, taken from the literature are given in Tables . In the majority of cases the free energies Δ G ≠ were calculated from the data on the coalescence of the NMR signals.…”
Section: Calculation Proceduresmentioning
confidence: 99%
“…From the coalescence of these signals one can calculate the Δ G ≠ values . This approach has been developed in many publications . In specific cases (Table , Series IX, XII) the free energies Δ G ≠ are determined from results of NMR line‐shape analysis …”
Section: Calculation Proceduresmentioning
confidence: 99%
“…IR-spectra of compounds in solution and in the solid state were recorded on a Bruker Tensor-27 spectrometer using KBr cells and an APR element, respectively. 1 H, 13 29 Si NMR spectra were recorded using the 1 H- 29 Si HSQC pulse sequence supplied with the Bruker Avance II 600 instrument. 23 The 1 H, 13 C, 29 Si chemical shis were measured using Me 4 Si as internal reference.…”
Section: Methodsmentioning
confidence: 99%
“…1 H, 13 29 Si NMR spectra were recorded using the 1 H- 29 Si HSQC pulse sequence supplied with the Bruker Avance II 600 instrument. 23 The 1 H, 13 C, 29 Si chemical shis were measured using Me 4 Si as internal reference. The 19 F chemical shis were measured using BF 3 as external reference.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation