2017
DOI: 10.1049/iet-pel.2015.1026
|View full text |Cite
|
Sign up to set email alerts
|

Steady‐state analysis of high‐voltage gain multiple series Z‐source inverter

Abstract: In this study, a new topology for multiple series Z-source inverter is proposed. The proposed topology only with one dc power source can generate output voltage higher than the conventional converter. This inverter has low voltage stress on capacitors and common ground between the input source and inverter. Also, the proposed topology with soft-start strategy has inherent ability to reduce inrush-current at start-up. First, different operating modes of the proposed inverter are investigated. Then, the voltage … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
1

Year Published

2018
2018
2021
2021

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 20 publications
(20 citation statements)
references
References 48 publications
(121 reference statements)
0
19
1
Order By: Relevance
“…According to (5), voltage across inductors is positive; so current through inductors is linearly increased from its minimum value (i L, min ) to its maximum value (i L, max ). The value of current through inductors is calculated as follows:…”
Section: First Operating Modementioning
confidence: 99%
See 3 more Smart Citations
“…According to (5), voltage across inductors is positive; so current through inductors is linearly increased from its minimum value (i L, min ) to its maximum value (i L, max ). The value of current through inductors is calculated as follows:…”
Section: First Operating Modementioning
confidence: 99%
“…It is noticeable that discussion on size of passive elements requires more precision because of the dependence on various factors. The size of inductors and capacitors usually is directly proportional to their stored energy and their number in the converter 5,39 ; so it is necessary to calculate stored energy in passive elements of the proposed and conventional Z-source inverters in the same conditions. Table 6 contains values of inductances, values of capacitances and values of stored energy in passive elements.…”
Section: Comparison Of Voltage Stress On Switchesmentioning
confidence: 99%
See 2 more Smart Citations
“…The Z-Source inverter is a power converter topology proposed in 2003 by Peng Fangzheng of Michigan State University [7]. The inverter can adjust the DC-link voltage and allow the shoot-through state [8][9][10]. The Z-Source network consists of two pairs of symmetrical inductors, capacitors, and an input diode.…”
Section: Introductionmentioning