2020
DOI: 10.2172/1608131
|View full text |Cite
|
Sign up to set email alerts
|

Status of GTA Gear Inspection after Testing in Sodium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…Calibration of raw EC data acquired with single-element probe was performed by using a reference block made of Inconel 718 material containing machined flaws in the form of flat bottom holes. The procedure was described in previous reports on this subject [3]. A different approach was adopted for the calibration of EC data acquired with array probes.…”
Section: Eddy Current Inspection Of Spur Gearsmentioning
confidence: 99%
See 1 more Smart Citation
“…Calibration of raw EC data acquired with single-element probe was performed by using a reference block made of Inconel 718 material containing machined flaws in the form of flat bottom holes. The procedure was described in previous reports on this subject [3]. A different approach was adopted for the calibration of EC data acquired with array probes.…”
Section: Eddy Current Inspection Of Spur Gearsmentioning
confidence: 99%
“…A different approach was adopted for the calibration of EC data acquired with array probes. A detailed description of the calibration procedure was presented in a previous report [3]. For the sake of completeness, a brief description of the procedure is provided here.…”
Section: Eddy Current Inspection Of Spur Gearsmentioning
confidence: 99%
“…As described in the previous reports on this subject, the main components of the system include the EC tester and probe assembly, a four-axis translation/rotation stage and a PC based motion control acquisition hardware and the associated software [1]. Software based tools including a number of algorithms for processing and visualization of EC inspection data have been developed and integrated into a common user interface under MATLAB environment.…”
Section: Eddy Current Inspection Of Spur Gearsmentioning
confidence: 99%
“…Calibration of raw EC data acquired with single-element probe was performed by using a reference block made of Inconel 718 material containing machined flaws in the form of flat bottom holes. The procedure was described in previous reports on this subject [1]. A different approach was adopted for the calibration of EC data acquired with array probes.…”
Section: Eddy Current Inspection Of Spur Gearsmentioning
confidence: 99%
See 1 more Smart Citation