2017 IEEE Energy Conversion Congress and Exposition (ECCE) 2017
DOI: 10.1109/ecce.2017.8095974
|View full text |Cite
|
Sign up to set email alerts
|

Stability improvement of current control by voltage feedforward considering a large synchronous inductance of diesel generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…Similar conclusion as (15) has been put forward by [23], [24]. References [23], [24] mainly focuses on the capability to suppress grid voltage harmonics of the ICF control, and proposes a complete CVF method, where the form of G vf (s) is expressed as (1+sG c (s)C f + s 2 L 1 C f ).…”
Section: Grid Voltage Harmonic Suppressionmentioning
confidence: 61%
See 2 more Smart Citations
“…Similar conclusion as (15) has been put forward by [23], [24]. References [23], [24] mainly focuses on the capability to suppress grid voltage harmonics of the ICF control, and proposes a complete CVF method, where the form of G vf (s) is expressed as (1+sG c (s)C f + s 2 L 1 C f ).…”
Section: Grid Voltage Harmonic Suppressionmentioning
confidence: 61%
“…So, all the parameters in (13) have been obtained (the parameters of the HPF are the same as Section III). In light of (13), there is an ideal situation: if G vf (s) satisfies the condition in (15), the harmonics of the grid voltage can be totally suppressed. But the condition in (15) includes a first-order derivative and a second-order derivative, which is impractical in digital control system.…”
Section: Grid Voltage Harmonic Suppressionmentioning
confidence: 99%
See 1 more Smart Citation
“…In a similar manner, when the 2ω 0 − ω p frequency components is considered, the power stage small signal model in stationary reference frame can be expressed as (19) where I p, 2ω 0 − ω p and D p, 2ω 0 − ω p are the phasors of the grid current and duty cycle responses at frequency 2ω 0 − ω p . The small signal model of the control loop in the dq frame is…”
Section: Equivalent Converter Impedance Model Considering Pll and Frementioning
confidence: 99%
“…Substituting (21) and 22into (20), and according to (19), we can obtain the coupling impedance for the response at…”
Section: Equivalent Converter Impedance Model Considering Pll and Frementioning
confidence: 99%