Stability evaluation of quartz crystal microbalances coated with polyvinyl acetate nanofibrous mats as butanol vapor sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

5
3

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 37 publications
0
13
0
Order By: Relevance
“…1. 50,51 PVAc (Sigma-Aldrich, molecular weight (M r ) 500 000 g mol À1 ) with a concentration of 15 wt% was mixed with citric acid (Merck) having different concentrations of 2, 4, 6, and 8 wt%. The mixture was then dissolved in N,N-dimethyl formamide (DMF) (Merck) and subsequently stirred at room temperature for 30 min at a stirring speed of 900 rpm to increase its solution homogeneity.…”
Section: Nanofiber Sensor Fabricationmentioning
confidence: 99%
See 1 more Smart Citation
“…1. 50,51 PVAc (Sigma-Aldrich, molecular weight (M r ) 500 000 g mol À1 ) with a concentration of 15 wt% was mixed with citric acid (Merck) having different concentrations of 2, 4, 6, and 8 wt%. The mixture was then dissolved in N,N-dimethyl formamide (DMF) (Merck) and subsequently stirred at room temperature for 30 min at a stirring speed of 900 rpm to increase its solution homogeneity.…”
Section: Nanofiber Sensor Fabricationmentioning
confidence: 99%
“…From our previous studies, it has been proven that the reduction of the active membrane surface area caused by swelling of the nanofibers is responsible for sensor performance degradation after several months of storage and use. 50,65 Fig. 6f shows the cross-sensitivity of the PVAc/CA8 nanofiber sensor exposed to various analyte vapors.…”
Section: Sensing Performancementioning
confidence: 99%
“…This gas sensing con guration utilizing microsyringe for vapor injection has already been used in our former experiments for other VOC sensor types (e.g., nano berfunctionalized QCMs). 36,70,71 Acetone was chosen as a VOC model because it is not only produced in the rebreathed breath (0.8 to 2.0 ppm) 72 but also indicated as one of the signi cant breath-borne COVID-19 biomarkers based on the study by Chen et al 62 Moreover, in the clinical practices, breath-containing acetone has also been extensively examined to diagnose some other diseases (i.e., lung cancer, diabetes mellitus, starvation, and ketogenic diet). 73 From the obtained measurement results shown in Figures S2b and c, the S3 and S7 sensors (or their extracted features of F3 and F7) demonstrated the poorest responses toward acetone vapors.…”
Section: Sensor Characteristics To Exhaled Breathsmentioning
confidence: 99%
“…Previous studies have demonstrated that adding some acid into the polymer structure proofs to enhance the sensitivity of the electrospun nanofiber to detect ammonia vapors. They used hydrophilic polymer, i. e., polyvinyl acetate (PVAc), as the template polymer [39–42] . Although the sensor shows a significant enhancement in the sensor sensitivity, the sensor dependence on the humidity changes during the detection process still becomes a setback.…”
Section: Introductionmentioning
confidence: 99%