2014
DOI: 10.1016/j.jelechem.2014.01.037
|View full text |Cite
|
Sign up to set email alerts
|

Square-wave voltammetric determination of hydroxychloroquine in pharmaceutical and synthetic urine samples using a cathodically pretreated boron-doped diamond electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
48
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 81 publications
(51 citation statements)
references
References 33 publications
2
48
0
1
Order By: Relevance
“…Artificial urine was synthesized using the following components: 0.73 g of NaCl, 0.40 g of KCl, 0.28 g of CaCl 2 , 0.56 g of Na 2 SO 4 , 0.35 g of KH 2 PO 4 , 0.25 g of NH 4 Cl, and 6.25 g of urea. The components were added to a 250 mL volumetric flask and the volume was completed with deionized water [32].…”
Section: Selectivity Experimentsmentioning
confidence: 99%
“…Artificial urine was synthesized using the following components: 0.73 g of NaCl, 0.40 g of KCl, 0.28 g of CaCl 2 , 0.56 g of Na 2 SO 4 , 0.35 g of KH 2 PO 4 , 0.25 g of NH 4 Cl, and 6.25 g of urea. The components were added to a 250 mL volumetric flask and the volume was completed with deionized water [32].…”
Section: Selectivity Experimentsmentioning
confidence: 99%
“…Taking into account the above and the excellent performance of BDD electrodes in the determination of many organic analytes 33,37,39,4550,55–57, in this paper, we report on the influence of electrochemical pretreatments on the activity of a BDD electrode for estrone detection, as well as on the development and validation of an analytical method to determine estrone in different water matrices using two voltammetric techniques: differential pulse voltammetry (DPV) and square‐wave voltammetry (SWV).…”
Section: Introductionmentioning
confidence: 98%
“…Here it should be noted that, for some analytes, the electroanalytical performance of BDD electrodes might depend on their surface termination (hydrogen or oxygen), which in principle can be tuned by cathodic or anodic electrochemical pretreatments, respectively 3745. Thus, cathodically pretreated BDD electrodes have been used to develop several electroanalytical procedures to determine different substances – see, for example, references 4650. Recently, Brocenschi et al.…”
Section: Introductionmentioning
confidence: 99%
“…As has been previously summarized [32], increased electroanalytical performances have been attained in the determination of additives in food products and drugs in pharmaceutical formulations after the BDD electrode was cathodically pretreated; more recently, this has happened e.g. for food colorants [33], and the pharmaceuticals albendazole [34], propylthiouracil [35], bezafibrate [36], hydroxychloroquine [37], hydroquinone [38], diclofenac [39], ciprofloxacin [40], and paracetamol/caffeine/orphenadrine [41] or propanolol/hydrochlorothiazide [42] simultaneously. However, in some cases, better results were attained with an anodically pretreated BDD electrode, e.g.…”
Section: Introductionmentioning
confidence: 99%