2011
DOI: 10.1080/00032711003790023
|View full text |Cite
|
Sign up to set email alerts
|

Square-Wave Anodic Stripping Voltammetry (SWASV) for the Determination of Ecotoxic Metals, Using a Bismuth-Film Electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0

Year Published

2012
2012
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(10 citation statements)
references
References 36 publications
1
9
0
Order By: Relevance
“…The theoretical detection limit was calculated by the equation DL= 3 σ bl /S , where σ bl is the standard deviation of the blank measurements and S is the sensitivity of the calibration plot. The detection limit of Pb 2+ was calculated as 2×10 −11 M. This value is significantly better in comparison with the previously reported detection limits for analysis of Pb 2+ at various electrodes and is comparable with the best recent ones 3234.…”
Section: Resultssupporting
confidence: 75%
“…The theoretical detection limit was calculated by the equation DL= 3 σ bl /S , where σ bl is the standard deviation of the blank measurements and S is the sensitivity of the calibration plot. The detection limit of Pb 2+ was calculated as 2×10 −11 M. This value is significantly better in comparison with the previously reported detection limits for analysis of Pb 2+ at various electrodes and is comparable with the best recent ones 3234.…”
Section: Resultssupporting
confidence: 75%
“…Also works for simultaneous determinations of bismuth with Cu and Pb using thymolphthalexone or nuclear fast red as a complexing agent [19][20][21] and for simultaneous determinations of cadmium mainly with Pb, Cu, Zn [22][23][24][25][26][27][28][29][30] and single procedures for simultaneous determination with Hg [23], Fe [31], Al [32], Tl [33] most of all by anodic stripping voltammetry [22,23,[25][26][27][28][29][30][31] infrequent adsorptive stripping voltammetry [30][31][32] But there is no method for simultaneous determination of bismuth and cadmium in a single scan. We have developed the procedure for simultaneous determination of Bi(III) and Cd(II) by adsorptive stripping measurements performed using cupferron as a complexing agent.…”
Section: Introductionmentioning
confidence: 99%
“…The previous UV digestion of the samples, as it was done in this work, is an effective procedure to overcome this problem [19] since it destroys the dissolved organic matter, which can complex trace metals or/and interact with the electrode materials, as surfactants. The comparative analysis of other works, where the simultaneous determination of metals, including Zn and Cu, were performed using bismuth electrodes [5,13 and references therein] evidences that in the present work low DLs and wider linear concentration ranges were achieved without being necessary additional reagents or the application of chemometric treatments [5,13].…”
Section: Simultaneous Determination Of Cu Hg Pb and Znmentioning
confidence: 78%