2012
DOI: 10.1016/j.jelechem.2012.05.020
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous voltammetric determination of trace bismuth(III) and cadmium(II) in water samples by adsorptive stripping voltammetry in the presence of cupferron

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
1

Year Published

2012
2012
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(17 citation statements)
references
References 44 publications
0
16
1
Order By: Relevance
“…This substance may be used in determination of Al(III) , U(VI) , Mo(VI) , Cd(II) , Zn(II) , Cr(VI) , Ti(IV) , Pb(II) , Ga(III) , Bi(III) , In(III) , and Cu(II) . Simultaneous determination of Bi(III) and Cd(II) , Bi(III) and Pb(II) , Cd(II) and Zn(II) , Pb(II) and V(V) , U(VI), Cd(II), and Pb(II) is possible.…”
Section: Introductioncontrasting
confidence: 59%
“…This substance may be used in determination of Al(III) , U(VI) , Mo(VI) , Cd(II) , Zn(II) , Cr(VI) , Ti(IV) , Pb(II) , Ga(III) , Bi(III) , In(III) , and Cu(II) . Simultaneous determination of Bi(III) and Cd(II) , Bi(III) and Pb(II) , Cd(II) and Zn(II) , Pb(II) and V(V) , U(VI), Cd(II), and Pb(II) is possible.…”
Section: Introductioncontrasting
confidence: 59%
“…It was proven in earlier papers that a simple, cheap and quick way to eliminate the interferences of organic substances in voltammetric determination is previous mixing of the analyzed sample with Amberlite XAD-7 resin [7][8][9][10][11]. Furthermore, in the case of the present procedure the addition to the sample of XAD-7 resin to allow elimination of the above-mentioned interferences was proposed.…”
Section: Analytical Applicationmentioning
confidence: 92%
“…In the case of analysis of environmental samples with organic-rich matrices the preliminary mixing with Amberlite XAD-7 resin was applied before analysis. The mixing with Amberlite XAD-7 resin, gives a superb effect as concerns the elimination of organic matrix interferences [7][8][9][10][11]. In this case, 0.5 g of resin was added to the sample solution with 4.5 cm 3 environmental water, 5 cm 3 triply distilled water, 0.5 cm 3 supporting electrolyte (CH 3 COOH) and proper concentration of 1•10 -4 mol/dm 3 Tytanit solution.…”
Section: Sample Preparationmentioning
confidence: 99%
“…99 100 Polymeric resins, such as Amberlite XAD-7 resin 99 and Amberlite XAD-16 100 were chose to eliminate the influence of organic substances.…”
Section: Electrochemical Techniquesmentioning
confidence: 99%