2012
DOI: 10.1016/j.ijms.2012.06.017
|View full text |Cite
|
Sign up to set email alerts
|

Spray mechanism in paper spray ionization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
155
0
3

Year Published

2014
2014
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 151 publications
(160 citation statements)
references
References 32 publications
2
155
0
3
Order By: Relevance
“…As a function of time, both the instantaneous analyte concentration in the spray solvent and the ionization efficiency may change. Moreover, there can also be changes in the physical parameters of the electrospray, including changes in droplet size distribution and flow rate [38]. These changes are thought to occur because of solvent depletion when the spray solvent is not replenished during analysis.…”
Section: Ion Suppression and Recovery Versus Timementioning
confidence: 99%
“…As a function of time, both the instantaneous analyte concentration in the spray solvent and the ionization efficiency may change. Moreover, there can also be changes in the physical parameters of the electrospray, including changes in droplet size distribution and flow rate [38]. These changes are thought to occur because of solvent depletion when the spray solvent is not replenished during analysis.…”
Section: Ion Suppression and Recovery Versus Timementioning
confidence: 99%
“…Ambient ionization [6][7][8][9][10][11][12][13][14] is a relatively recent approach to MS analysis which avoids chromatography and is characterized by the absence of any requirement for sample preparation. Paper spray ionization [15][16][17][18][19][20] is a particularly simple ambient ionization technique which can be employed to study reactions and identify intermediates as well as to measure trace constituents of complex mixtures. Like other spray ionization methods, paper spray is least successful for non-polar or weakly polar compounds.…”
Section: Introductionmentioning
confidence: 99%
“…An investigation of the impacts to PSI-MS performance by the substrates, solvents and elution methods were reported by Ren et al 72) A higher voltage (±3.5 kV) is usually applied to PSI-MS. Espy et al have particularly focused on the voltage applied for spraying and the correct positioning of the paper tip in front of the inlet of the MS spectrometer. 78) In addition, the angle of the paper tip also plays a key role in the generation of the spray. In their results showed that paper spray operates in two distinct spray modes.…”
Section: Paper Spray Ionization (Psi)mentioning
confidence: 99%
“…e cone-jet diameters were approximately 1-10 µm in diameter, and smaller but out-of-focus jets are also produced. 78,79) e electrospray droplet size is dependent on not only applied voltage, but also the solvent composition and the ow rate.…”
Section: Paper Spray Ionization (Psi)mentioning
confidence: 99%