2011
DOI: 10.1016/j.jcjo.2011.09.006
|View full text |Cite
|
Sign up to set email alerts
|

Spectral-domain optical coherence tomography for early glaucoma assessment: analysis of macular ganglion cell complex versus peripapillary retinal nerve fiber layer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
42
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 59 publications
(42 citation statements)
references
References 30 publications
0
42
0
Order By: Relevance
“…18 Evidence is accumulating that measurements of the inner retinal layers in the macular region may be additional parameters for glaucoma detection. [4][5][6]19,20 Previous studies have shown that GCC and cpRNFL thickness exhibit similar diagnostic performance for the detection of early glaucoma. 5,21 The first report by Schulze et al using RTVue (mean MD in the glaucomatous eyes ¼À1.76 dB) demonstrated that the AUCs of the average cpRNFL and GCC thickness were 0.828 and 0.789, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…18 Evidence is accumulating that measurements of the inner retinal layers in the macular region may be additional parameters for glaucoma detection. [4][5][6]19,20 Previous studies have shown that GCC and cpRNFL thickness exhibit similar diagnostic performance for the detection of early glaucoma. 5,21 The first report by Schulze et al using RTVue (mean MD in the glaucomatous eyes ¼À1.76 dB) demonstrated that the AUCs of the average cpRNFL and GCC thickness were 0.828 and 0.789, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, the likely false positive rate of such a diagnostic test (i.e., macular full-thickness analysis) might be high. The measurement of perifoveal GCC thickness has emerged as a new early diagnostic parameter of glaucoma in recent years [14]. It has been reported that glaucoma preferentially affects GCC rather than all macular layers [15].…”
Section: Discussionmentioning
confidence: 99%
“…10 Segmented measurements of the macular region have been suggested as a useful tool for structural assessment of glaucomatous patients. [11][12][13] For example, Rao and colleagues have compared RNFL and macular thickness measurements for glaucoma detection. They included 140 eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects and showed that both parameters have a good ability to detect eyes with glaucomatous VF loss with sensitivities at 80% specificity of 80.0% for RNFL thickness and 80.7% for ganglion cell complex (GCC), respectively.…”
mentioning
confidence: 99%
“…The sensitivities at 80% specificity for average GCC and pRNFL thickness were 66.7% (cutoff, 89.9 mm) and 62.9% (cutoff, 111.8 mm), respectively. 11 The RTVue-100 (Optovue Inc., Fremont, CA), one of the commercially available SDOCT devices, has a scan rate of 26,000 A-scans per second and an axial resolution of 5 mm. 14,15 The high scanning speed of the RTVue enables the acquisition of a greater number of scans in a single imaging session compared with time-domain OCT, reducing the need for data interpolation and motion artifacts.…”
mentioning
confidence: 99%
See 1 more Smart Citation