Spectral calibration of radiometric detectors using tunable laser sources

Abstract: This paper describes the analysis of laser-based responsivity measurements using the Tunable Lasers in Photometry setup at the Physikalisch-Technische Bundesanstalt. An approach based on digital signal analysis is proposed to remove interference-caused oscillations in highly resolved spectral data from laser-based measurements, yielding an improved reproducibility and comparability of results. Digital filters are used to selectively suppress the frequency components of interference fringes visible in the measu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 24 publications
(18 citation statements)
references
References 12 publications
0
18
0
Order By: Relevance
“…The laser system is described in [17]. The measurements were carried out at four wavelengths: 400 nm, 515 nm, 680 nm, and 800 nm.…”
Section: Angular Dependencementioning
confidence: 99%
“…The laser system is described in [17]. The measurements were carried out at four wavelengths: 400 nm, 515 nm, 680 nm, and 800 nm.…”
Section: Angular Dependencementioning
confidence: 99%
“…The absolute spectral radiance responsivity of the LP3 obtained with the two facilities are plotted over the measured wavelength range on a logarithmic scale in Figure 3 and close to the center wavelength showing the bandpass region on a linear scale in Figure 4 with the spectral bandwidth of 1 nm for the monochromator-based facility. The results from the laser-based facility in the wavelength range between 535 nm to 618 nm are given after applying the correction algorithm [9]. From Figure 3, it can be clearly seen that out-of-band responsivity values of the LP3 by the monochromatorbased measurement are at least one order of magnitude larger than that from the laser-based measurement due to the higher noise level.…”
Section: Comparison Resultsmentioning
confidence: 99%
“…Thereby the frequency components resulting from the interference fringes are selectively damped using digital filtering according to the scheme in Figure 5. The detailed method is described in [9]. As can be seen in Figure 4, significant differences between spectral responsivity values from both facilities were found at some wavelength range.…”
Section: Comparison Resultsmentioning
confidence: 99%
See 2 more Smart Citations