2018
DOI: 10.1049/iet-gtd.2017.0860
|View full text |Cite
|
Sign up to set email alerts
|

Specifying angular reference for three‐phase distribution system state estimators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 26 publications
0
10
0
2
Order By: Relevance
“…State estimation in distribution systems requires considering three-phase voltage phase angles at the reference bus due to their unbalanced nature. While current solutions typically involve modeling to determine these angles [33,34], this paper proposes relying on measurements to obtain these variables. Discrete Fourier transform (DFT) or any other phasor estimation method can be applied to the measured signal of three-phase voltages at the reference bus.…”
Section: A Obtaining Voltage Phase Angles Of the Reference Busmentioning
confidence: 99%
See 2 more Smart Citations
“…State estimation in distribution systems requires considering three-phase voltage phase angles at the reference bus due to their unbalanced nature. While current solutions typically involve modeling to determine these angles [33,34], this paper proposes relying on measurements to obtain these variables. Discrete Fourier transform (DFT) or any other phasor estimation method can be applied to the measured signal of three-phase voltages at the reference bus.…”
Section: A Obtaining Voltage Phase Angles Of the Reference Busmentioning
confidence: 99%
“…Considering balanced voltage phase angles for the reference bus might decrease the accuracy of the estimator. The use of a virtual reference bus is an alternative solution for this problem in the literature [33,34]. However, as described in Section III, the phase angles of voltage phasors at the reference bus can be directly calculated.…”
Section: B Dealing With the Reference Bus Voltage Phase Anglesmentioning
confidence: 99%
See 1 more Smart Citation
“…Alternatively, the slack bus can be modelled as a balanced threephase voltage source behind an equivalent impedance that represents the system upstream the distribution substation [35]. Resultantly, the three-phase voltages at the substation bus will be unbalanced according to the imbalances of the distribution system.…”
Section: Slack Busmentioning
confidence: 99%
“…When the measurements in polar coordinates obtained from the PMUs are converted into the rectangular coordinates, and the power measurements are converted into the equivalent current measurements, the measurement error transmission is involved. The covariance of equivalent measurements [35] can be obtained through measurement correlation, and the covariance matrix of the branch current measurements in rectangular coordinate can be expressed as Equation 6:…”
Section: State Variables and Measurement Equations In Robust State Esmentioning
confidence: 99%