Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2021
DOI: 10.1016/j.talanta.2020.121972
|View full text |Cite
|
Sign up to set email alerts
|

Speciation of germanium in environmental water reference materials by hydride generation and cryotrapping in combination with ICP-MS/MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
10
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 12 publications
(17 citation statements)
references
References 45 publications
2
10
0
Order By: Relevance
“…Arsenic speciation analysis was performed simultaneously in the samples (As results not presented in this study), a method compatible with both elements needed to be adopted. Thus, an adaptation of hydride generationcryotrappinginductively coupled plasma mass spectrometry (HG-CT-ICP MS/MS) element-dedicated methods previously described for speciation analysis of As and Ge was used: while the system setup and ICP-MS/MS setting were identical as described for Ge (García-Figueroa et al, 2021), reagent concentrations and flow rates corresponded to the optimum values for As analysis (Matoušek et al, 2013). They were, however, entirely compatible with Ge speciation analysis.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Arsenic speciation analysis was performed simultaneously in the samples (As results not presented in this study), a method compatible with both elements needed to be adopted. Thus, an adaptation of hydride generationcryotrappinginductively coupled plasma mass spectrometry (HG-CT-ICP MS/MS) element-dedicated methods previously described for speciation analysis of As and Ge was used: while the system setup and ICP-MS/MS setting were identical as described for Ge (García-Figueroa et al, 2021), reagent concentrations and flow rates corresponded to the optimum values for As analysis (Matoušek et al, 2013). They were, however, entirely compatible with Ge speciation analysis.…”
Section: Discussionmentioning
confidence: 99%
“…Generated volatile (methylated) hydrides were collected, preconcentrated and separated in a quartz U-tube filled with approximately 0.9 g of Chromosorb WAW-DMCS 45/60, 15% OV-3 (Supelco). Cooling of U-tube and heating for sequential desorption of hydrides were performed in a semi-automated system on a Perkin-Elmer FIAS unit (García-Figueroa et al, 2021). ICP MS/MS Agilent 8900 in O 2 mode with mass shift (m/z 72->88) was used for detection.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations