2007 Power Conversion Conference - Nagoya 2007
DOI: 10.1109/pccon.2007.372949
|View full text |Cite
|
Sign up to set email alerts
|

Space Vector Modulated and Vector Controlled Vienna I Rectifier with Active Filter Function

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(16 citation statements)
references
References 8 publications
0
16
0
Order By: Relevance
“…The synchronous reference frame controllers usually use the space vector modulators (SVM) to calculate the time divisions of the selected voltage space vectors. Using different duty-ratios and switching sequence for each phase, the control schemes can be configured to take different performance properties into prior consideration [15][16][17][18][19], such as neutral point voltage balancing, switching loss minimization, algorithm simplification, and etc. In addition, the zero-sequence reference injection can also be utilized in this controller.…”
Section: Imentioning
confidence: 99%
“…The synchronous reference frame controllers usually use the space vector modulators (SVM) to calculate the time divisions of the selected voltage space vectors. Using different duty-ratios and switching sequence for each phase, the control schemes can be configured to take different performance properties into prior consideration [15][16][17][18][19], such as neutral point voltage balancing, switching loss minimization, algorithm simplification, and etc. In addition, the zero-sequence reference injection can also be utilized in this controller.…”
Section: Imentioning
confidence: 99%
“…In [6] and [7], Vienna rectifiers with added active filter functionality in three-phase three-wire and three-phase four-wire systems have been reported, respectively, but integrating reactive power compensation function into Vienna rectifiers is not mentioned in either study. In [8], integrating harmonic current compensation (HCC) and reactive power compensation (RPC) functionality into the Vienna rectifiers is investigated, and a conclusion is given based on theoretical analysis, which states that because of the unidirectional power flow characteristic, Vienna rectifiers have only limited RPC capability.…”
Section: Introductionmentioning
confidence: 99%
“…Compared with the bidirectional rectifier, the unidirectional rectifier adopts fewer fully controlled power switches, which greatly increases the power density of the system and reduces the implementation costs [14]. Taking these considerations into account, many literatures have proposed and demonstrated the potential of unidirectional rectifier that provides RPC or HCC functionalities to mitigate reactive and harmonic currents produced by non-linear loads and uncontrolled passive loads [15][16][17][18][19][20][21].…”
Section: Introductionmentioning
confidence: 99%