2019
DOI: 10.1049/iet-pel.2018.6233
|View full text |Cite
|
Sign up to set email alerts
|

Power factor adjustment and input current distortion mitigation for three‐phase unidirectional rectifier

Abstract: In order to improve the power quality, many researchers in the worldwide are committed to investigating the feasibility of integrating reactive power compensation (RPC) and harmonic current compensation (HCC) functionalities for unidirectional rectifier, while the capability of RPC for unidirectional rectifier is very limited. Hence, with the aim of enlarging the capability of RPC for unidirectional rectifier, this article introduces a versatile control strategy for three-phase star-connected unidirectional re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 24 publications
0
2
0
Order By: Relevance
“…The results show that each of the topologies possesses several advantages and disadvantages. Although the bidirectional rectifier exhibits the characteristic of low THD input current, and those types of topologies are appropriate for the However, in order to improve the THD performance for the unidirectional topologies, the control methods have been modified to decrease the distortion of the input current, and to increase the controllability angle [28][29][30].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The results show that each of the topologies possesses several advantages and disadvantages. Although the bidirectional rectifier exhibits the characteristic of low THD input current, and those types of topologies are appropriate for the However, in order to improve the THD performance for the unidirectional topologies, the control methods have been modified to decrease the distortion of the input current, and to increase the controllability angle [28][29][30].…”
Section: Resultsmentioning
confidence: 99%
“…The distortions of the input current will become more severe while the leading or lagging angle is increased, so the controllability angle for unidirectional rectifier is limited. However, in order to improve the THD performance for the unidirectional topologies, the control methods have been modified to decrease the distortion of the input current, and to increase the controllability angle [28][29][30].…”
Section: Thd Analysis Of Input Currentmentioning
confidence: 99%