2021
DOI: 10.1002/pat.5209
|View full text |Cite
|
Sign up to set email alerts
|

Sorption of cobalt (II) and chromium (III) ions to nitrogen‐ and sulfur‐containing polyampholyte on the basis of polyvinylchloride

Abstract: In this article, we studied the process of obtaining nitrogen‐ and sulfur‐containing polyampholyte by chemical modification of sulphocation exchanger. Which is synthesized based on polyvinyl chloride (PVC), with polyethylenepolyamine. Besides, the PVC and synthesized ion exchange resins were characterized using different tools such as FT‐IR, scanning electron microscope, and energy‐dispersive X‐ray. Moreover, the synthesized polyampholyte was used as effective adsorbents for removing Co (II) and Cr (III) ions … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 32 publications
0
9
0
1
Order By: Relevance
“…The amount of hexavalent chromium ions absorbed in the anion exchanger is calculated by the following equation: qe=C0Cem×V, where q e is the amount of metal ion absorbed into the anion exchanger (mol/g), C 0 is the initial concentration of Cr (VI) ions (mol/L), C e is the equilibrium concentration of Cr (VI) ions (mol/L), V is the solution volume (l), and m is the dry adsorbent mass (g) 31 …”
Section: Methodsmentioning
confidence: 99%
“…The amount of hexavalent chromium ions absorbed in the anion exchanger is calculated by the following equation: qe=C0Cem×V, where q e is the amount of metal ion absorbed into the anion exchanger (mol/g), C 0 is the initial concentration of Cr (VI) ions (mol/L), C e is the equilibrium concentration of Cr (VI) ions (mol/L), V is the solution volume (l), and m is the dry adsorbent mass (g) 31 …”
Section: Methodsmentioning
confidence: 99%
“…Since chromium (III) ions are absorbed more than cobalt (II) ions, the radius of the Cr 3 + ion is explained by the fact that the radius of the Co 2 + ion is smaller. It was also shown 34 that metal ions are sorbed by polyampholyte both by ionic and coordination bonds (Scheme 10).…”
Section: Modified Pvc Through Nitrogen Containing Reagents (Pvc‐n) An...mentioning
confidence: 99%
“…According to the authors, Cr 3 + ions are absorbed more than Co 2 + ions, respectively, 3.97 and 3.45 mmol/g during the sorption of Co 2 + and Cr 3 + metal ions on polyampholyte. 34 Since chromium (III) ions are absorbed more than cobalt (II) ions, the radius of the Cr 3 + ion is explained by the fact that the radius of the Co 2 + ion is smaller. It was also shown 34 Since PVC is comparatively cheap polymer, it is so economical to use PVC-based membranes in the membrane separation processes.…”
Section: S C H E M E 5 Crosslinking Of the Pvc With Liquid Ammoniamentioning
confidence: 99%
See 1 more Smart Citation
“…Cинтезированный полиамфолит использовался в качестве эффективных адсорбентов для удаления ионов Co (II) и Cr (III) из водных растворов [22][23][24]. В работах [25][26][27][28][29][30][31][32] приведены результаты исследования адсорбционных характеристик полимерной матрицы, модифицированной хелатирующими агентами нового поколения.…”
Section: Introductionunclassified