2012
DOI: 10.1016/j.biosystemseng.2012.09.006
|View full text |Cite
|
Sign up to set email alerts
|

Sonic anemometry to evaluate airflow characteristics and temperature distribution in empty Mediterranean greenhouses equipped with pad–fan and fog systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
26
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 51 publications
(29 citation statements)
references
References 35 publications
3
26
0
Order By: Relevance
“…Our results are consistent with findings of past studies by Kittas et al (2001Kittas et al ( , 2003; Bartzanas & Kittas (2005); Al-Helal et al (2006); Teitel et al (2010); Lopez et al (2012) related to the temperature and humidity distributions. For example, in a study performed by (26 Ağustos 2009);Sensör konumları: 1, dış;2, pad;3, pade yakın;4, orta;5, fana yakın (26 Ağustos 2009);Sensör konumları: 1, dış;2, pad;3, pade yakın;4, orta;5, fana yakın Bartzanas & Kittas (2005), the difference between the air temperature entering to greenhouse and outside air temperature was about 10 °C.…”
Section: Internal Conditionssupporting
confidence: 94%
See 2 more Smart Citations
“…Our results are consistent with findings of past studies by Kittas et al (2001Kittas et al ( , 2003; Bartzanas & Kittas (2005); Al-Helal et al (2006); Teitel et al (2010); Lopez et al (2012) related to the temperature and humidity distributions. For example, in a study performed by (26 Ağustos 2009);Sensör konumları: 1, dış;2, pad;3, pade yakın;4, orta;5, fana yakın (26 Ağustos 2009);Sensör konumları: 1, dış;2, pad;3, pade yakın;4, orta;5, fana yakın Bartzanas & Kittas (2005), the difference between the air temperature entering to greenhouse and outside air temperature was about 10 °C.…”
Section: Internal Conditionssupporting
confidence: 94%
“…It was observed that the cooled air temperature levels passing the wet pad with air velocity of 0.8-0.9 m s -1 were approximately 12-13 °C lower than the outside air temperature. The maximum air velocity measured in front of Pads inside of the greenhouse was 0.9 m s -1 , but as moving away from Pads, it was observed that the air velocities reduced up to 0.2 -0.3 m s -1 in crop rows, which were also consistent with results obtained by Li & Willits (2008); Lopez et al (2012). ASABE (2008) has recommended the mean air velocity of 1.27 m s -1 entering to the greenhouse through the pad.…”
Section: Internal Conditionssupporting
confidence: 91%
See 1 more Smart Citation
“…High-temperature gradients of this type can markedly affect plant growth, and growers often combine cooling pads with shading, (Kittas, et al, 2003). The air saturation efficiency of the pad-fan system is greater than that of the fog system (Katsoulas et al, 2009); it is also cheaper (Sethi and Sharma, 2007a) and it consumes less water and energy (López et al, 2012). However, it requires extremely airtight greenhouse structures to ensure that all incoming air passes through the evaporative pads along part or the whole of the side wall, with powerful extractor fans being placed along the opposite wall to provide the required suction.…”
Section: Introductionmentioning
confidence: 99%
“…Experiments in a greenhouse integrated with the ground heat storing system were conducted to evaluate the effectiveness of the control system. According to López et al, (2012) in a greenhouse equipped with evaporative pads a difference in temperature of up to 11.6 °C was recorded with respect to a naturally ventilated greenhouse, whereas using the fog system this difference was 10.4 °C. The main drawback of the pad-fan system was the horizontal temperature gradients, with a maximum difference of 11.4 °C between the pads and the fans.…”
Section: Introductionmentioning
confidence: 99%