2012
DOI: 10.1016/j.talanta.2012.02.053
|View full text |Cite
|
Sign up to set email alerts
|

Solidified floating organic drop microextraction combined with ETV-ICP-MS for the determination of trace heavy metals in environmental water samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 54 publications
(18 citation statements)
references
References 37 publications
0
18
0
Order By: Relevance
“…Unfortunately, liquid nebulization sample introduction procedure for conventional ICP-MS is not compatible with SFODME because of its large sample consumption. Therefore, a lot of works on SFODME for separation and preconcentration of trace elements have been done by AAS, but only few researches were reported using ICP-MS (Chen, Cheng, He, Zhu, & Lu, 2013;Guo, He, Chen, & Hu, 2012).…”
Section: Introductionmentioning
confidence: 99%
“…Unfortunately, liquid nebulization sample introduction procedure for conventional ICP-MS is not compatible with SFODME because of its large sample consumption. Therefore, a lot of works on SFODME for separation and preconcentration of trace elements have been done by AAS, but only few researches were reported using ICP-MS (Chen, Cheng, He, Zhu, & Lu, 2013;Guo, He, Chen, & Hu, 2012).…”
Section: Introductionmentioning
confidence: 99%
“…The limit of detection for the analytes and preconcentration factors for the procedure were better than results from reported methods. [46][47][48][49] World Health Organization / Food and Agriculture Organization [40] 0.30 5.0 [41] Solid phase extraction with gallic acidmodified silica gel 100-200 0. 65-0.58 [42] Coprecipitation with copper(II)-rubeanic acid 25-50 0.58-3.4 [43] Solid phase extraction with oligosilsesquioxane sorbent based on Nanosilicate -0.41-0.47 [44] Coprecipitation 50 0.34-0.87 [45] Solidified floating organic drop microextraction -electrothermal vaporization -inductively coupled plasma mass spectrometry 20-324 0.0020-0.0170 [46] Single solidified floating organic drop …”
Section: Discussionmentioning
confidence: 99%
“…The presented novel microextraction showed a relatively high enrichment factor and low detection limit compared with reports in the literature. [43][44][45][46][47][48][49] …”
Section: Comparison With Other Preconcentration Techniquesmentioning
confidence: 99%
“…Moreover, Guo et al. used a chelating agent for better extraction of heavy metal ions. It can be seen that there are many ways to influence the extraction, such as varying the type of solvent, its volume, addition of salt, stirring rate, temperature, etc.…”
Section: Sdmementioning
confidence: 99%
“…Lower boiling solvent p-xylene was mixed with 1-dodecanol in a ratio such that the drop was still stable but the extract evaporated at lower temperature, which is advantageous for GC. Moreover, Guo et al [44] used a chelating agent for better extraction of heavy metal ions. It can be seen that there are many ways to influence the extraction, such as varying the type of solvent, its volume, addition of salt, stirring rate, temperature, etc.…”
Section: Sd-lpmementioning