2013
DOI: 10.1364/oe.21.013758
|View full text |Cite
|
Sign up to set email alerts
|

Snapshot 3D optical coherence tomography system using image mapping spectrometry

Abstract: Abstract:A snapshot 3-Dimensional Optical Coherence Tomography system was developed using Image Mapping Spectrometry. This system can give depth information (Z) at different spatial positions (XY) within one camera integration time to potentially reduce motion artifact and enhance throughput. The current (x,y,λ ) datacube of (85×356×117) provides a 3D visualization of sample with 400 μm depth and 13.4 μm in transverse resolution. Axial resolution of 16.0 μm can also be achieved in this proof-of-concept system.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 25 publications
(15 citation statements)
references
References 36 publications
0
15
0
Order By: Relevance
“…Representative techniques in this category are 3D integral imaging [147], single-shot digital holography [148], and snapshot 3D optical coherence tomography [149]. …”
Section: Snapshot Multidimensional Imaging Implementations and Appmentioning
confidence: 99%
See 2 more Smart Citations
“…Representative techniques in this category are 3D integral imaging [147], single-shot digital holography [148], and snapshot 3D optical coherence tomography [149]. …”
Section: Snapshot Multidimensional Imaging Implementations and Appmentioning
confidence: 99%
“…A representative technique is snapshot 3D optical coherence tomography (OCT) [149]. In spectral-domain OCT, the photons scattered from different depth layers exhibit different modulation frequencies in the spectrum [190].…”
Section: Snapshot Multidimensional Imaging Implementations and Appmentioning
confidence: 99%
See 1 more Smart Citation
“…It is not applicable to a continuous stream of data where a high frame rate camera is necessary. The technique should be expandable to capture a 3D volume in a single pulse with the application of 2D to 1D mapping such as that used in [11]. Further orders of magnitude decrease of the temporal gate, thus increase of the equivalent A-Scan rate, should be possible with the use of femtosecond laser sources.…”
Section: Single Pulse Imaging Of Pharmaceutical Coated Tabletmentioning
confidence: 99%
“…Line Field SD-OCT (LF-OCT) [10] captures a whole cross-sectional image (B-Scan) or even a three dimensional volume [10,11] in a single shot, instead of just a single A-Scan. It does this by using an imaging spectrograph.…”
Section: Introductionmentioning
confidence: 99%