2002
DOI: 10.1016/s0021-9290(01)00224-x
|View full text |Cite
|
Sign up to set email alerts
|

Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

8
95
0

Year Published

2003
2003
2016
2016

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 94 publications
(103 citation statements)
references
References 16 publications
8
95
0
Order By: Relevance
“…The 50% lower wear rate of the TKR inserts compared with the THR liners for regular wear (no delamination) may be a result of the lower degree of multidirectional motion in the knee [18,31]. This comparison entailed adjusting the wear rates to a patient age of 70 years to account for age dependence, and included only active patients.…”
Section: Discussionmentioning
confidence: 99%
“…The 50% lower wear rate of the TKR inserts compared with the THR liners for regular wear (no delamination) may be a result of the lower degree of multidirectional motion in the knee [18,31]. This comparison entailed adjusting the wear rates to a patient age of 70 years to account for age dependence, and included only active patients.…”
Section: Discussionmentioning
confidence: 99%
“…In actual prosthetic joints, not only the contact pressure but also the size and shape of the slide track varies considerably on the contact surfaces [Saikko and Calonius, 2002b]. It may not be possible to determine a characteristic wear factor for every type of slide track.…”
Section: Discussionmentioning
confidence: 99%
“…15,21 Analysis of the wear paths produced by different simulators has shown a wide variation, ranging from simple linear paths with infinite aspect ratios to open circular paths with low aspect ratios. 22 The potential importance of variations in individual THA patient's wear paths on wear rates has recently been recognized, with altered gait cycle inputs used to predict wear rate in a finite element model.…”
Section: Discussionmentioning
confidence: 99%
“…Three-dimensional wear paths were determined for a sample of 20 points on the acetabulum and two-dimensional projected plots of the wear paths were produced. [14][15][16] The aspect ratios of the 2D wear paths was used to determine the degree of linear or multidirectional motion experienced at the hip. Larger aspect ratios indicated more longitudinal paths, while smaller ratios indicated more wide or open paths.…”
Section: Methodsmentioning
confidence: 99%