2020
DOI: 10.1109/tia.2020.3003856
|View full text |Cite
|
Sign up to set email alerts
|

Six-Leg Single-Phase AC–DC–AC Multilevel Converter With Transformers for UPS and UPQC Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(6 citation statements)
references
References 29 publications
1
5
0
Order By: Relevance
“…The use of a z-source network in the converter not only addresses the shoot-through issue but also helps in the adjustment of the required voltage gain. The existing topologies of the indirect AC-AC converters are reported in [17][18][19][20][21]. The stability analysis and several modulation schemes for a DC-link capacitor are stated in [17,18].…”
Section: Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…The use of a z-source network in the converter not only addresses the shoot-through issue but also helps in the adjustment of the required voltage gain. The existing topologies of the indirect AC-AC converters are reported in [17][18][19][20][21]. The stability analysis and several modulation schemes for a DC-link capacitor are stated in [17,18].…”
Section: Literature Reviewmentioning
confidence: 99%
“…The stability analysis and several modulation schemes for a DC-link capacitor are stated in [17,18]. The power quality-related issues in AC-DC-AC converters are reported in the multilevel converter approach in [19][20][21]. The DC-link capacitors employed in indirect AC-AC converters are electrolytic capacitors that are sizeable and have short operation life.…”
Section: Literature Reviewmentioning
confidence: 99%
“…V o = DV s (10) By employing a similar methodology, the voltage step-down inverting behavior of the proposed circuit can also be validated with equivalent circuits and mathematical equations. This mode produced an inverted form of the input voltage at the output, and this is simply turning on the low-frequency transistors T r4 , T r5 and T r2 , T r6 for positive and negative input voltage by maintaining the switching role of T r1 and T r3 unchanged.…”
Section: Non-inverting and Inverting Buck Operationmentioning
confidence: 99%
“…The traditional way to resolve these issues is the use of indirect approaches of AC-AC conversion [7][8][9][10]. That requires power conversion in two stages where a DC-link capacitor is a mandatory requirement between the two converters.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation