2021
DOI: 10.3390/app112411944
|View full text |Cite
|
Sign up to set email alerts
|

A New Dual Polarity Direct AC-AC Voltage Regulator Ensuring Voltage Step-Up and Step-Down Capabilities

Abstract: The problem of voltage sag and swell is one of the major reasons for low-quality power in the distribution system. Normally, it results from the system’s faults, including line-to-ground and line-to-line, non-linear characteristics of loads and sources. Its effect is very serious for the critical loads as their performance is very sensitive to the variation in voltage. The stabilization of voltage is a mandatory requirement in such a situation. The correction of such problems requires the addition and subtract… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 25 publications
(51 reference statements)
0
3
0
Order By: Relevance
“…The instantaneous values of the voltage and current may regard constant as their variation can be ignored at high switching frequencies. The value of switching losses for the existing circuits of [23,25,26] and the proposed topology in Equations ( 41)-( 44) respectively may be realized with the procedure as detailed in [28,29].…”
Section: Comparison With Similar Topologiesmentioning
confidence: 99%
See 1 more Smart Citation
“…The instantaneous values of the voltage and current may regard constant as their variation can be ignored at high switching frequencies. The value of switching losses for the existing circuits of [23,25,26] and the proposed topology in Equations ( 41)-( 44) respectively may be realized with the procedure as detailed in [28,29].…”
Section: Comparison With Similar Topologiesmentioning
confidence: 99%
“…The main source of the conversion losses consists of conduction losses (especially for diode and thyristors) and line frequency input transformer. The conduction losses in the topologies reported in [23,25,26] and the developed circuit are calculated from Equations ( 45)-( 48) respectively by following the procedure adopted in [29]. In these equations, the notation V f is used to represent the value of the forward voltage of a diode or a thyristor.…”
Section: Comparison With Similar Topologiesmentioning
confidence: 99%
“…Because of this, the lifespan of the DC-link AC/AC power converter device prematurely shortens due to the usage of the most prevalent electrolytic capacitors [18][19][20]. For the aforementioned reasons, environmental and operational factors impacting the longevity of power converters, particularly high-power ones, are given special consideration, with a focus on DC-link capacitors [21]. An intriguing way to lower the price and size of power converters is to produce them without huge capacitors in their design (DC-link) [22,23].…”
Section: Introductionmentioning
confidence: 99%