Abstract: In previous work we demonstrated how a confocal microscope with a spatial light modulator in the back focal plane could perform accurate measurement of the k-vector of a propagating surface plasmon. This involved forming an embedded interferometer between light incident close to normal incidence (reference beam) and light incident at the angle to excite surface plasmons (sample beam). The signal from the interferometer was extracted by stepping the phase of the reference beam relative to the sample beam using … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 11 publications
0
9
0
Order By: Relevance
“…In other words, the rougher surface led to the worse refractive index sensing capability. This contour was then normalized to the maximum calculated FOM and curve-fitted to polynomial function FOM(h, cl), as expressed in Equation (12), with an R 2 of 99.98%, using the built-in curve-fitting toolbox in MATLAB. Figure 16b shows the curve-fitted contour based on the curve-fitting model.…”
Section: Effect Of Roughness On the Spr Figure Of Merit (Fom)mentioning
confidence: 99%
See 2 more Smart Citations
“…In other words, the rougher surface led to the worse refractive index sensing capability. This contour was then normalized to the maximum calculated FOM and curve-fitted to polynomial function FOM(h, cl), as expressed in Equation (12), with an R 2 of 99.98%, using the built-in curve-fitting toolbox in MATLAB. Figure 16b shows the curve-fitted contour based on the curve-fitting model.…”
Section: Effect Of Roughness On the Spr Figure Of Merit (Fom)mentioning
confidence: 99%
“…Table 2 shows the performance parameters calculated for the idealized smooth surface and different plasmonic gold sensor roughness reported in the literature for different deposition technologies and surface treatments calculated using Equations ( 8)- (12). The surface RMS reported in the literature were extracted from each of the referenced articles in Table 2 and then converted to corresponding h and cl values using Equation (2), assuming the h and 1/cl had a similar length, as reported by Agarwal et al [51].…”
Section: Plasmonic Sensing Responses Of Different Depositions and Surface-treatment Technologiesmentioning
confidence: 99%
See 1 more Smart Citation
“…The k sp,BSA uniform and k sp,WATER uniform are the plasmonic angles measured for the uniform layer of the BSA protein and the bare gold sensor, respectively. (18) where Ct ,water grating and Ct ,BSA grating are the measurement crosstalk at the center of the water region and the center of the BSA region in the grating sample, respectively.…”
Section: Comparative Performance Parametersmentioning
confidence: 99%
“…Thanks to the development in high numerical aperture (NA) objective lenses, they have made SP excitation more convenient under a conventional optical microscope configuration [ 16 , 17 ]. Several SPR microscope configurations [ 18 , 19 ] can achieve good sensitivity without compromising the spatial resolution. The SPR microscopes have demonstrated their capability in microscopic scale biosensing applications, such as recently, an SPR microscope has been employed to measure the binding kinetics of spike protein in SARS CoV-2 or COVID-19 virus with angiotensin-converting enzyme 2 (ACE2) [ 20 ].…”
Section: Introductionmentioning
confidence: 99%