2009 Brazilian Power Electronics Conference 2009
DOI: 10.1109/cobep.2009.5347655
|View full text |Cite
|
Sign up to set email alerts
|

Single-phase distributed generation system based on asymmetrical cascaded multilevel inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 5 publications
0
4
0
1
Order By: Relevance
“…One of the main advantages in the use of an LMI-based problem is that it can be solved without further complications by a great variety of solvers as the LMI MATLAB® Toolbox [37]. The solution for the problem posed in (15) leads to the determination of an optimal upper bound for ∥ H yw ∥ ∞ (16), and to the definition of the also optimal H ∞ state feedback controller gains (17).…”
Section: Robust H ∞ Grid Current Controllermentioning
confidence: 99%
See 2 more Smart Citations
“…One of the main advantages in the use of an LMI-based problem is that it can be solved without further complications by a great variety of solvers as the LMI MATLAB® Toolbox [37]. The solution for the problem posed in (15) leads to the determination of an optimal upper bound for ∥ H yw ∥ ∞ (16), and to the definition of the also optimal H ∞ state feedback controller gains (17).…”
Section: Robust H ∞ Grid Current Controllermentioning
confidence: 99%
“…For this reason, the use of such filters demands the adoption of peak damping strategies also as presented in [13,14], being passive or active damping methods. In the light of that, the case study covered by this work regards a grid-connected PV generation system in which the grid-interactive inverter is based on the asymmetrical cascaded multilevel topology [15,16]. Multilevel inverters can offer an output voltage composed by more voltage levels when compared to conventional three-level PMW inverters.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This topology permits the switching of the higher power cells at fundamental frequency, reducing the switching losses of the inverter and thus improving efficiency. However, this advantage is also its important weakness since the power is not evenly distributed among the inverter cells, mitigating the input current low order harmonics elimination effect of the multipulse rectifier system of the conventional CHB [39,42]. 19-level ACHB-MFGCI configuration is shown in Fig.…”
Section: Recent Advances In Vsml-mfgci Topologies Used In Pv Systemsmentioning
confidence: 99%
“…Por fim, a validação da proposta é feita através dos resultados de simulações e experimentais que mostram a capacidade do sistema de geração em transferir potência constante para a rede de distribuição e manter a corrente quase sem distorções em fase com a tensão. ENSLIN, 1996;SONG et al, 2001;BOR-REN;YI-LANG, 2002), a em cascata simétrica (FANG ZHENG et al, 1996;MCKEEVER;ADAMS, 1998;YIQIAO;NWANKPA, 1999;CHUL-WOO et al, 2002;LI et al, 2003;GENG;YONGDONG;XIAOJIE, 2004;MASSOUD;FINNEY;WILLIAMS, 2004), e a em cascata assimétrica (PATIL et al, 1999;LEE;RON HUI;HENRY SHU-HUNG, 2002;LOPEZ et al, 2003;HONGFA;XIANZHONG;QINGCHUN, 2005;ORTUZAR et al, 2006;PIMENTEL;POMILIO, 2008;PIMENTEL;MARTINEZ;POMILIO, 2009;PIMENTEL, 2011 (FANG ZHENG et al, 1996;HAMMOND, 1997;JOOS;XIAOGANG;BOON-TECK, 1998;SCHIBLI;TUNG;RUFER, 1998;HABETLER, 1999;RODRIGUEZ et al, 2002). A seção seguinte apresenta as motivaçõ...…”
unclassified