Single-brand dual-chamber discriminators to prevent inappropriate shocks in patients implanted with prophylactic implantable cardioverter defibrillators: a propensity-weighted comparison of single- and dual-chamber devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…Propensity-score matched analysis of registry data in primary prevention ICD recipients has also suggested that dual-chamber devices have a lower rate of inappropriate shock compared with single-chamber devices. [ 23 ] In that analysis, independent predictors of inappropriate shock included a history of AF, chronic kidney disease and non-ischaemic cardiomyopathy, while PR Logic was the only discriminator that was related to a lower risk of inappropriate shock along with an SVT rate limit programmed to >200 BPM. [ 23 ]…”
Section: Dual-chamber Discriminatorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Propensity-score matched analysis of registry data in primary prevention ICD recipients has also suggested that dual-chamber devices have a lower rate of inappropriate shock compared with single-chamber devices. [ 23 ] In that analysis, independent predictors of inappropriate shock included a history of AF, chronic kidney disease and non-ischaemic cardiomyopathy, while PR Logic was the only discriminator that was related to a lower risk of inappropriate shock along with an SVT rate limit programmed to >200 BPM. [ 23 ]…”
Section: Dual-chamber Discriminatorsmentioning
confidence: 99%
“…[ 23 ] In that analysis, independent predictors of inappropriate shock included a history of AF, chronic kidney disease and non-ischaemic cardiomyopathy, while PR Logic was the only discriminator that was related to a lower risk of inappropriate shock along with an SVT rate limit programmed to >200 BPM. [ 23 ]…”
Section: Dual-chamber Discriminatorsmentioning
confidence: 99%
“…Also, morphology as a single discriminator has limited sensitivity for appropriate diagnosis of ventricular arrhythmias [66]. Similar to pacemakers, dual-chamber devices are associated with improved detection of AHRE as well as with fewer inappropriate shocks [9,24].…”
Section: Implantable Cardioverterdefibrillatorsmentioning
confidence: 99%