2010
DOI: 10.1016/j.radonc.2010.01.011
|View full text |Cite
|
Sign up to set email alerts
|

Single Arc Volumetric Modulated Arc Therapy of head and neck cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

12
140
6
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 167 publications
(159 citation statements)
references
References 24 publications
12
140
6
1
Order By: Relevance
“…The doses delivered were measured using the PTW 2D‐ARRAY seven29 (PTW, Freiburg, Germany) with a 2D detector matrix with 729 cubic ionization chambers. ( 47 ) Comparison was performed using the Verisoft software (PTW), and gamma (Γ2mm,3%) evaluations ( 15 , 16 , 48 ) were calculated (the dose criterion was ±3% and the distance criterion was 3 mm).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The doses delivered were measured using the PTW 2D‐ARRAY seven29 (PTW, Freiburg, Germany) with a 2D detector matrix with 729 cubic ionization chambers. ( 47 ) Comparison was performed using the Verisoft software (PTW), and gamma (Γ2mm,3%) evaluations ( 15 , 16 , 48 ) were calculated (the dose criterion was ±3% and the distance criterion was 3 mm).…”
Section: Methodsmentioning
confidence: 99%
“…( 8 13 ) The novel TPS SmartArc, developed by Philips Radiation Oncology Systems (Philips, Fitchburg, WI, USA) in collaboration with RaySearch Laboratories AB (Stockholm, Sweden) and which builds on the existing direct machine parameter optimization (DMPO) ( 14 ) functionality in Pinnacle3, has recently become clinically and commercially available and can generate VMAT planning for both Elekta (Elekta Ltd., Crawley, UK) and Varian accelerators. ( 15 17 ) Another RaySearch‐based and linear accelerator (linac) vendor‐independent TPS, Oncentra MasterPlan v.3.3 (Nucletron BV, Veenendaal, The Netherlands), became clinically available in December 2009 and permits VMAT optimization for both linacs. The underlying VMAT planning engine in both SmartArc and Oncentra MasterPlan TPS is the same as that developed by RaySearch, and the dose calculation algorithms of pencil beam (PB) convolution and collapsed cone convolution (CCC) were chosen.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The use of VMAT in head and neck treatments may offer a combination of reduced treatment time, better organ‐at‐risk (OAR) sparing, or increased target dose conformality compared to other treatment types 2 , 3 , 4 , 5 . Many head and neck treatment plans include regional lymph nodes in the supraclavicular area.…”
Section: Introductionmentioning
confidence: 99%
“…Many of the developments have related to formalizing and improving the efficiency of inverse planning, 2 , 3 such that highly modulated and conformal dose distributions can now be achieved for a range of sites 4 , 6 . Just as significant are the advances in linear accelerator design — particularly in the ability of linac control systems to now reliably vary gantry speed, dose rate, and aperture shape simultaneously over the treatment arc (7) .…”
Section: Introductionmentioning
confidence: 99%