2008
DOI: 10.4103/0973-8398.43299
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous spectrophotometric estimation of rabeprazole sodium and itopride hydrochloride in capsule formulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…Besides, the criteria of the dual wavelength method for choosing the two wavelengths so that; one component showed different absorbance at the two selected wavelengths while the other component shows same absorbance at these wavelengths as upon subtraction it will be cancelled, makes the proposed ratio difference method simpler, more precise and more reliable as the ratio spectrum of the interfering component will show the same amplitudes (constant). The whole analysis is carried out using distilled water as solvent which ensures that the methods are environmentally safe compared to other reported methods [35,36,[38][39][40][41]. Generally, the suggested methods have minimum requirements compared to the previously reported spectrophotometric ones; it is not conditional to have isoabsorptive point, extension of one component than the other or zero crossing [33][34][35][36][37], which make the proposed methods more widely applied for the analysis of the cited drugs or other binary mixtures having sever overlapping spectra.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Besides, the criteria of the dual wavelength method for choosing the two wavelengths so that; one component showed different absorbance at the two selected wavelengths while the other component shows same absorbance at these wavelengths as upon subtraction it will be cancelled, makes the proposed ratio difference method simpler, more precise and more reliable as the ratio spectrum of the interfering component will show the same amplitudes (constant). The whole analysis is carried out using distilled water as solvent which ensures that the methods are environmentally safe compared to other reported methods [35,36,[38][39][40][41]. Generally, the suggested methods have minimum requirements compared to the previously reported spectrophotometric ones; it is not conditional to have isoabsorptive point, extension of one component than the other or zero crossing [33][34][35][36][37], which make the proposed methods more widely applied for the analysis of the cited drugs or other binary mixtures having sever overlapping spectra.…”
Section: Resultsmentioning
confidence: 99%
“…The whole analysis is carried out using distilled water as solvent which ensures that the methods are environmentally safe compared to other reported methods [35,36,[38][39][40][41]. Generally, the suggested methods have minimum requirements compared to the previously reported spectrophotometric ones; it is not conditional to have isoabsorptive point, extension of one component than the other or zero crossing [33][34][35][36][37], which make the proposed methods more widely applied for the analysis of the cited drugs or other binary mixtures having sever overlapping spectra.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The literature survey revealed that several methods have been reported for the individual estimation of rabeprazole sodium and itopride hydrochloride and in combination with other drugs by UV [3][4][5][6][7] , HPLC [8][9][10][11][12][13][14][15][16][17][18] and HPTLC [19][20][21][22] . However there is no method reported for the simultaneous analysis of the same combination by HPLC.…”
Section: Figure 2 Structure Of Itopride Hydrochloridementioning
confidence: 99%