Simultaneous Quantitative Analysis of Shikonin and Deoxyshikonin in Rat Plasma by Rapid LC–ESI–MS–MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 23 publications
0
9
0
1
Order By: Relevance
“…Data were collected in negative ion mode using an extended dynamic range (2 GHz). Additional LC/MS-MS experimentation was performed for selected molecules of interest ( Huang et al , 2010 ) using analytical standards of acetylshikonin (MW 330.1103; RT 5.75 min±0.7min), deoxyshikonin (MW 272.1048; RT 6.75±0.7min), dimethylacrylshikonin (MW 370.1416; RT 7.7 min±0.7min) purchased from ChemFaces (Wuhan, China) and shikonin (MW 288.0997; RT 3.51 min±0.7min) obtained from Biomol (Hamburg, Germany). All data were analysed using MassHunter software (ver.…”
Section: Methodsmentioning
confidence: 99%
“…Data were collected in negative ion mode using an extended dynamic range (2 GHz). Additional LC/MS-MS experimentation was performed for selected molecules of interest ( Huang et al , 2010 ) using analytical standards of acetylshikonin (MW 330.1103; RT 5.75 min±0.7min), deoxyshikonin (MW 272.1048; RT 6.75±0.7min), dimethylacrylshikonin (MW 370.1416; RT 7.7 min±0.7min) purchased from ChemFaces (Wuhan, China) and shikonin (MW 288.0997; RT 3.51 min±0.7min) obtained from Biomol (Hamburg, Germany). All data were analysed using MassHunter software (ver.…”
Section: Methodsmentioning
confidence: 99%
“…To verify this possible molecular binding activity, an antibody pull-down assay in combination with LC-MS/MS analysis was employed to determine the intracellular interaction between SK and hnRNPA1 protein. The chromatographic and mass spectrometric conditions for detection of SK in this assay were optimized from a previous report [28]. The production spectrum of an SK standard (Figure 1a) showed a significant precursor ion signal (m/z = 287.0921) and the MS/MS fragmental spectra for its precursor showed a major fragment (m/z = 218.0226).…”
Section: Resultsmentioning
confidence: 99%
“…The workflow used for detecting SK using LC-MS/MS has been previously described [28]. In this study, the LC-MS/MS analysis performance was further optimized by coupling an ultrahigh performance liquid chromatography (UPLC) system (ACQUITY UPLC, Waters, Millford, MA) to an ultrahigh resolution tandem mass spectrometer (LTQ Orbitrap Elite, Thermo Fisher Scientific, Bremen, Germany).…”
Section: Methodsmentioning
confidence: 99%
“…The method was validated according to the literature [11] and FDA guideline [12]. Validation runs were conducted on three consecutive days.…”
Section: Validation Of the Methodsmentioning
confidence: 99%