2021
DOI: 10.1016/j.foodchem.2020.127602
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous quantification of eleven bioactive phenolic compounds in pigeon pea natural resources and in vitro cultures by ultra-high performance liquid chromatography coupled with triple quadrupole mass spectrometry (UPLC-QqQ-MS/MS)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 37 publications
0
16
0
Order By: Relevance
“…Fragment ions m / z 283 were generated as m / z 341continued to lose one molecule of H 2 O and CO. When compared with the standard information and literature [ 29 ], compound 10 was identified as vitexin.…”
Section: Resultsmentioning
confidence: 99%
“…Fragment ions m / z 283 were generated as m / z 341continued to lose one molecule of H 2 O and CO. When compared with the standard information and literature [ 29 ], compound 10 was identified as vitexin.…”
Section: Resultsmentioning
confidence: 99%
“…In addition, the effective chromatographic separation of analytes is important to evade ionization intrusion in the mass source, which will be beneficial for refining the sensitivity and accuracy in the entire analysis. 23 Therefore, some critical parameters such as column selection, mobile phases, and gradient programs can significantly influence the chromatographic separation ability. These optimized conditions will be helpful to improve the peak resolution, boost the signal response, and shorten the running time for the simultaneous analysis of 16 targeted phenolic components.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Efficient chromatographic separation of analytes is important to avoid ionization interference in the MS source, which is good for improving the sensitivity and accuracy of the entire analysis [30] . Initially, the Waters ACQUITY UPLC ® BEH C18 column (100 mm × 2.1 mm, 1.7 μm) exhibited excellent performance by comparing several UPLC-analysis columns in our laboratory.…”
Section: Resultsmentioning
confidence: 99%
“…The validation of the proposed quantitation method was performed according to international guidelines in terms of specificity, linearity, sensitivity, stability, repeatability, accuracy and matrix effect [30] .…”
Section: Resultsmentioning
confidence: 99%