Simultaneous online measurement of sulfide and nitrate in sewers for nitrate dosage optimisation

Abstract: A new method for the simultaneous online measurement of sulfide and nitrate in wastewater is developed. A UV-VIS spectrometer was used. The sensor was calibrated by means of simultaneous online and offline measurements of sulfide and nitrate in batch tests carried out on a laboratory-scale sewer system. The developed calibration algorithm was successfully validated for both sulfide and nitrate measurement, with confidence limits of 2.7 mg S/L for total dissolved sulfide, and 7.5 mg N/L for nitrate. The online … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 11 publications
1
10
0
Order By: Relevance
“…Dissolved sulfide in R1 and R3 was measured continuously by using an s::can spectro::lyser UV-visible (UV-Vis) spectrometer probe (Messtechnik GmbH, Austria) (28). For the analysis of dissolved sulfur species, 1.5 ml of wastewater was filtered through disposable Millipore filter units (0.22-m pore size) and added to 0.5 ml preserving solution antioxidant buffer (SAOB) (29).…”
Section: Methodsmentioning
confidence: 99%
“…Dissolved sulfide in R1 and R3 was measured continuously by using an s::can spectro::lyser UV-visible (UV-Vis) spectrometer probe (Messtechnik GmbH, Austria) (28). For the analysis of dissolved sulfur species, 1.5 ml of wastewater was filtered through disposable Millipore filter units (0.22-m pore size) and added to 0.5 ml preserving solution antioxidant buffer (SAOB) (29).…”
Section: Methodsmentioning
confidence: 99%
“…Dissolved sulfide and nitrate was simultaneously measured in continuous by means of an UVeVIS spectrometer probe s::can spectro::lyser (Messtechnik, GmbH, Austria) (Gutierrez et al, 2010b). Dissolved sulfur species (sulfate, sulfide, sulfite and thiosulfate) were measured offline via ion chromatography (IC) with a UV and conductivity detector (Dionex ICS-5000).…”
Section: Chemical Analysismentioning
confidence: 99%
“…The need for more cost-effective methods for H 2 S and CH 4 mitigation has led to the development of new nitrate dosing strategies based on improved dosage rates and dosing locations. For instance, Gutierrez et al (2010b) tested seven different nitrate dosing strategies in a laboratory-scale sewer system, providing strong support to H 2 S-control optimization. The results showed the benefits of adding nitrate at a point close to the end of the pipe, named Downstream Nitrate Dosage (DND).…”
Section: Introductionmentioning
confidence: 99%
“…Recent development of the UV-vis spectroscopy technology allows the simultaneous monitoring of dissolved sulfide and nitrate [67,68]. Another sensor has been developed more recently, which is able to measure dissolved sulfide and dissolved methane simultaneously with the use of an automated stripping chamber and gas-phase hydrogen sulfide and methane sensors [69].…”
Section: Modelling and Monitoring Of Sewer Processes And Concrete Cormentioning
confidence: 99%