Simultaneous measurements of thermal conductivity and thermal diffusivity of liquids under microgravity conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
59
0

Year Published

2003
2003
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 70 publications
(61 citation statements)
references
References 4 publications
2
59
0
Order By: Relevance
“…Some of these issues can be overcome by determining an effective length and diameter for the wire in a fluid/gas of known properties. This approach has also been used successfully in the transient short-hot-wire method [6].…”
Section: Summary and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Some of these issues can be overcome by determining an effective length and diameter for the wire in a fluid/gas of known properties. This approach has also been used successfully in the transient short-hot-wire method [6].…”
Section: Summary and Discussionmentioning
confidence: 99%
“…For high-pressure hydrogen, a small pressure vessel is required for safety and ease of conformity with high-pressure gas regulations. The transient short-hot-wire method [6] overcomes the difficulty of the sample size but for low-density gases the temperature rise of the wire is still strongly influenced by 5 10 50 100 500 1000 It is clear from Fig. 1 that the wire heat capacity is largely responsible for the non-linearity in the three-omega voltage component versus frequency curve and end effects are important in the low-frequency range.…”
Section: Introductionmentioning
confidence: 99%
“…Since the detailed principle and procedure of the TSHW technique have been described previously [12][13][14] . The coefficients A and B, the slope and intercept, are determined by the least-squares method for a relevant range of Fourier number corresponding to the measuring periods.…”
Section: Methodsmentioning
confidence: 99%
“…Since a detailed description of the principle is given in a previous study [2], its outline will be described below.…”
Section: Principle Of Measurementsmentioning
confidence: 99%
“…The authors have proposed a transient short-hot-wire method [1], developed from the conventional transient hot-wire method, and have confirmed the reliability of the method by conducting simultaneous measurements of the thermal conductivity and thermal diffusivity of liquids such as pure water, toluene, and so on [2]. Further, by coating the short-hot-wire probe (length: 10 mm, diameter: 50 µm to 100 µm, aspect ratio L: 100 to 200) with about a 5-µm-thick film of alumina, the authors have tried to measure the thermal conductivity and thermal diffusivity of electrically conducting and highly corrosive molten salts like Li 2 CO 3 -K 2 CO 3 (70/30 mol%) and Li 2 CO 3 -Na 2 CO 3 (53/47 mol%) [3,4].…”
Section: Introductionmentioning