2022
DOI: 10.1109/jlt.2021.3120868
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Measurement of Seawater Temperature and Pressure With Polydimethylsiloxane Packaged Optical Microfiber Coupler Combined Sagnac Loop

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 30 publications
(8 citation statements)
references
References 38 publications
0
7
0
Order By: Relevance
“…Junyang Lu conducted studies on pressure and temperature dual-parameter sensors based on polymer-coated tapered optical fiber [ 77 , 78 , 79 ]. This sensor is based on their previous study of an optical microfiber couple combined Sagnac loop [ 80 ]. The schematic structure of the sensor is shown in Figure 7 a.…”
Section: Temperature Sensorsmentioning
confidence: 99%
“…Junyang Lu conducted studies on pressure and temperature dual-parameter sensors based on polymer-coated tapered optical fiber [ 77 , 78 , 79 ]. This sensor is based on their previous study of an optical microfiber couple combined Sagnac loop [ 80 ]. The schematic structure of the sensor is shown in Figure 7 a.…”
Section: Temperature Sensorsmentioning
confidence: 99%
“…However, sensors based on TF are generally fragile, due to the waist diameter being down to the micron or even nanometer level. Thus, some protection and package measures must be considered, such as with the assistance of Polydimethylsiloxane (PDMS) [ 60 ].…”
Section: Sensors Based On Magnetic Fluid (Mf)mentioning
confidence: 99%
“…So, some polymers with high TOC and high elasticity are used to cover the microfiber for this purpose, such as PDMS. For example, a PDMS-immersed OMC−Sagnac hybrid structure is proposed to realize simultaneous measurement of TP with sensitivities of −2.133 nm/°C and 3.416 nm/MPa [ 115 ]. Similarly, by immersing the whole in-line MMZI into PDMS, sensing of TP in seawater with high sensitivity can also be realized with sensitivities of −7.41 nm/°C and 13.31 nm/MPa, respectively ( Figure 5 c) [ 116 ].…”
Section: Ofs For Multi-parameter Sensing and Measurement In Tspmentioning
confidence: 99%
“…For example, Liu et al realized a response time of 33 ms in salinity sensing [ 104 ]; Hou et al obtained response times of 1.13 s and 286 ms in TP sensing [ 116 ]. In the TP sensing, Lu et al obtained response times of 2.6 s and 960 ms, respectively [ 115 ]. By optimizing the encapsulation, the response time after encapsulation of MMZI in TS sensing was about 219.0 ms and 12.5 ms, respectively [ 136 ].…”
Section: Practical Application Of Optical Fiber Sensors In Ocean Obse...mentioning
confidence: 99%