2016
DOI: 10.18052/www.scipress.com/ilns.54.100
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Generation of Bioelectricity and Treatment of Swine Wastewater in a Microbial Fuel Cell

Abstract: This study aimed at the simultaneous treatment of wastewater obtained from swine and generation of bioenergy in form of electricity from the energy stored in the organic component of the wastewater. The Open circuit voltage, current, power density and microbiological and physicochemical parameters were monitored. An initial Open circuit voltage of 516mV, Current of 0.29mA, and Power density of 32.74mW/m2were recorded, which increased to give maximum Open Circuit Voltages of 836mV, Current of 0.49mA, and Power … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 20 publications
(14 reference statements)
0
4
0
Order By: Relevance
“…Other researchers using swine wastewater showed ammonium removal and an increase of the nitrate and nitrite concentrations most likely due to nitrification at the cathode surface due to the presence of oxygen (Egbadon et al, ; Min et al, ). Our system shows an opposite trend to what has been reported in the MFC literature to date.…”
Section: Resultsmentioning
confidence: 94%
See 2 more Smart Citations
“…Other researchers using swine wastewater showed ammonium removal and an increase of the nitrate and nitrite concentrations most likely due to nitrification at the cathode surface due to the presence of oxygen (Egbadon et al, ; Min et al, ). Our system shows an opposite trend to what has been reported in the MFC literature to date.…”
Section: Resultsmentioning
confidence: 94%
“…The system was operated for 76 days, and the COD removal efficiency in this case was up to 91%. Another high COD removal efficiency of 86% was reported from Egbadon et al (), who used a dual‐chamber MFC with ferricyanide as a catholyte and a total working volume of 1.0 liter. The system was operated in batch mode with a HRT of 21 days.…”
Section: Introductionmentioning
confidence: 85%
See 1 more Smart Citation
“…Copyright  Aiyer KS Lesser extent of biofilm formation on anodes present in diluted wastewaters lead to smaller peak heights. The results likely indicate that the mechanism of electricity generation was by direct transfer of electrons to the electrode by bacteria present on the anode surface [40].…”
Section: Gr Up Smmentioning
confidence: 95%