SAE Technical Paper Series 1997
DOI: 10.4271/971610
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Fast Response NO and HC Measurements from a Spark Ignition Engine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
20
0

Year Published

1999
1999
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(20 citation statements)
references
References 9 publications
0
20
0
Order By: Relevance
“…Reavell et al [5] have noted that the NO traces they obtained had a similar 'signature'. They deduced that the initial peak in the signal, point A in Fig.…”
Section: Fast No Measurementsmentioning
confidence: 84%
See 1 more Smart Citation
“…Reavell et al [5] have noted that the NO traces they obtained had a similar 'signature'. They deduced that the initial peak in the signal, point A in Fig.…”
Section: Fast No Measurementsmentioning
confidence: 84%
“…When the piston was close to BDC, both transducers recorded the cylinder pressure, thereby fixing the pressure datum for the piezoelectric transducer in the cylinder head. The operation of a fast chemiluminescent detector (CLD) has recently been described by Reavell et al [5] and allows fast transient measurements of NO exhaust emissions. An instrument of this type was recently reported by Baltisberger and Ruhm [6].…”
Section: Experimental Facilitymentioning
confidence: 99%
“…NO calibration gas was used as a tracer, and its local concentration was measured using a Cambustion fNOx400 fast-response NO analyzer. This instrument utilizes a chemillumeniscence detector (CLD) similar to standard 'steady' NO analyzers, except the detector is mounted remotely at the measurement position and is sized to provide dynamic response on the order of 2-3 ms. A thorough discussion of fast-response chemillumeniscence analyzer system dynamics can be found in [19], and the technical details of this particular instrument can be found in [20].…”
Section: Fast-response Tracer-gas Measurementmentioning
confidence: 99%
“…Recently, ultra-fast response gas analysers have been used to provide high spatio-temporal resolution RDE data from vehicles [11,12]. Such analysers, which have a response time of a few milliseconds, have been used for a long time in engine development, for example in cyclically resolved engine measurements [13,14], cold start [15,16], and emission reduction [17,18]. Their use in RDE enables correlations of vehicle emissions to manoeuvres by the vehicle, for example pulling away from traffic lights, joining a motorway, or going over a speed-bump.…”
Section: Introductionmentioning
confidence: 99%