Simultaneous determination of iron and nickel in fluoropolymers by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry

Abstract: This paper reports the development of a method of simultaneous determination of iron and nickel in fluoropolymers by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) with direct solid sampling. In order to carry out simultaneous measurements, both the main resonance line of nickel (232.003nm) and the adjacent secondary line of iron (232.036nm) were monitored in the same spectral window. The proposed method was optimized with a perfluoroalkoxy (PFA) sample and was … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(12 citation statements)
references
References 27 publications
0
11
0
1
Order By: Relevance
“…143 Solid-sampling fl ame AAS (HR-CS-F AAS) has a number of limitations associated with the sensitivity of determination and interference. Therefore, atomic absorption analysis of solid samples can be best done using HR-CS graphite furnace atomic absorption spectrometry (HR-CS-GF AAS) (see Refs 19,22,23,[27][28][29][43][44][45][47][48][49]58,70,73,76,77,89,101,102,108,116,126,131,132).…”
Section: Solid-sampling High-resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (Hr-cs-gf Aas)mentioning
confidence: 99%
See 1 more Smart Citation
“…143 Solid-sampling fl ame AAS (HR-CS-F AAS) has a number of limitations associated with the sensitivity of determination and interference. Therefore, atomic absorption analysis of solid samples can be best done using HR-CS graphite furnace atomic absorption spectrometry (HR-CS-GF AAS) (see Refs 19,22,23,[27][28][29][43][44][45][47][48][49]58,70,73,76,77,89,101,102,108,116,126,131,132).…”
Section: Solid-sampling High-resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (Hr-cs-gf Aas)mentioning
confidence: 99%
“…Simultaneous determination of iron and nickel in thermoplastic polyesters by solid-sampling HR-CS-GF AAS was reported. 131 The method involved simultaneous determination of analytes in the same spectral range by monitoring the main resonance line of nickel (232.003 nm) and the neighboring secondary line of iron (232.036 nm). The technique was optimized by using perfl uoroalkoxyalkane and used for the determination of iron and nickel in fl uorinated ethylene propylene and modifi ed polytetrafl uoroethylene with Pd and H 2 (in the pyrolysis stage) being chemical modifi ers.…”
Section: Analysis Of Coals and Graphite By Hr-cs-gf Aasmentioning
confidence: 99%
“…Therefore, a rapid and precise analytical method for the determination of nickel is essentially required for the production control of spoolable reinforced plastic line pipe. Numerous analytical methods were employed for the determination of nickel in different types of matrices including atomic absorption spectrometry [2,3], atomic emission spectrophotometry [4], molecular fluorescence spectroscopy [5], electroanalytical method [6] and spectrophotometry [7,8]. Spectrophotometric methods occupy special position due to their simplicity, less expensive instrumentation and high sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, a rapid and precise analytical method for the determination of nickel is essentially required for the production control of spoolable reinforced plastic line pipe. Numerous analytical methods were employed for the determination of nickel in different types of matrices including atomic absorption spectrometry [2,3], atomic emission spectrophotometry [4], molecular fluorescence spectroscopy [5], electroanalytical method [6] and spectrophotometry [7,8]. Spectrophotometric methods occupy special position due to their simplicity, less expensive instrumentation and high sensitivity.…”
Section: Introductionmentioning
confidence: 99%