2011
DOI: 10.1016/j.jchromb.2011.07.013
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of ascorbic acid, aminothiols, and methionine in biological matrices using ion-pairing RP-HPLC coupled with electrochemical detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0
1

Year Published

2012
2012
2022
2022

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 25 publications
(8 citation statements)
references
References 58 publications
0
7
0
1
Order By: Relevance
“…Additionally, many GSSG measurements are based upon the reduction of the disulphide followed by measurement of GSH [24]. In order to avoid sample pretreatment some investigators have utilised electrochemical detection (ECD) to directly and simultaneously measure GSH and GSSG [25,26]. The sensitive nature of ECD lends itself to the analysis of GSSG which can be difficult to measure due to its low endogenous concentration.…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, many GSSG measurements are based upon the reduction of the disulphide followed by measurement of GSH [24]. In order to avoid sample pretreatment some investigators have utilised electrochemical detection (ECD) to directly and simultaneously measure GSH and GSSG [25,26]. The sensitive nature of ECD lends itself to the analysis of GSSG which can be difficult to measure due to its low endogenous concentration.…”
Section: Introductionmentioning
confidence: 99%
“…Нами також запропонований кінетичний метод диференційного визначення АК та цистеїну (Цис) [9] у сумішах, певним недоліком якого є довготривалість та складність визначення. Досі немає простих спектрофотометричних методик визначення АК у присутності тіолів [17][18][19][20][21][22]…”
Section: введенняunclassified
“…The nine compounds and the IS were separated within 25 min, and their LODs ranged from 0.6 to 25 ng/mL at an S/N ratio of 3. Furthermore, an ion-pairing reversed-phase-HPLC-ECD method was reported [67] in which total Cys, Hcy, and GSH were reduced by TCEP, and Met and ASA in human plasma and blood cell were determined with LODs of 60-80 pg/mL in a total analysis time of 20 min. More recently, Hannan et al reported an HPLC-ECD method for nine compounds and malondialdehyde in rabbit serum [68], allowing the endogenous antioxidant capacity and lipid peroxidation level to be monitored simultaneously.…”
Section: Electrochemical Detectionmentioning