2013
DOI: 10.1016/j.jpba.2013.05.009
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of 38 phosphodiestrase-5 inhibitors in illicit erectile dysfunction products by liquid chromatography–electrospray ionization-tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
18
0

Year Published

2014
2014
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 44 publications
(18 citation statements)
references
References 22 publications
(46 reference statements)
0
18
0
Order By: Relevance
“…Adulteration is an exemplary repercussion of such laxity. Well documented are instances of diuretics, stimulants, anorectics, or oxidative uncouplers contained in weight loss supplements [60][61][62][63][64][65][66][67][68][69][70][71][72][73][74], steroids in performance enhancers [75][76][77][78][79][80], and phosphodiesterase 5 inhibitors contained within male enhancement products [72,74,[81][82][83][84][85][86][87][88][89][90][91][92][93]. At least nine people died in Sweden following exposure to Kratom adulterated with Odesmethyltramadol, a potent opioid analgesic.…”
Section: Supplement Regulationmentioning
confidence: 99%
“…Adulteration is an exemplary repercussion of such laxity. Well documented are instances of diuretics, stimulants, anorectics, or oxidative uncouplers contained in weight loss supplements [60][61][62][63][64][65][66][67][68][69][70][71][72][73][74], steroids in performance enhancers [75][76][77][78][79][80], and phosphodiesterase 5 inhibitors contained within male enhancement products [72,74,[81][82][83][84][85][86][87][88][89][90][91][92][93]. At least nine people died in Sweden following exposure to Kratom adulterated with Odesmethyltramadol, a potent opioid analgesic.…”
Section: Supplement Regulationmentioning
confidence: 99%
“…Such approach does not provide as high level of identification reliability as is achieved by comparisons with standards, but it was considered acceptable for the purpose of screening and more economical than purchasing many standards. The LC/MS data was searched for the accurate masses (±25 ppm window) of 67 PDE5 inhibitors listed in recent review articles focused on this class of drugs [15,16] (extracted ion chromatograms and corresponding structures are given in Supporting Information). Positive samples are summarized in Table 1.…”
mentioning
confidence: 99%
“…For most of the detected PDE5 inhibitors, the CID fragments matched those reported in the literature. [15,16] In a few cases, it took more effort to conclude about the identity of the observed species. In the CID spectra of ions with m/z corresponding to protonated cinnamyldenafil (samples #2 and #3, mass errors 3.1 and 2.9 ppm, respectively, Table 1), only one product ion (m/z 117) was observed of the two reported in the literature (m/z 115 and 117).…”
mentioning
confidence: 99%
See 2 more Smart Citations